PHOENIX CONTACT PLC-V8C/PT-24DC/RS485 PLC-V8C/PT-24DC/RS485 1452919 PHOENIX CONTACT PLC logic basic module, with RS-485 connection for Modbus/RTU,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-V8C/PT-24DC/RS485 1452919 PHOENIX CONTACT PLC logic basic module, with RS-485 connection for Modbus/RTU,..

PLC-V8C/PT-24DC/RS485

1452919

PHOENIX CONTACT

1 Pcs.

PLC logic basic module, with RS-485 connection for Modbus/RTU, with 16 I/O, pluggable into 8 digital or analogue PLC-INTERFACE terminals, expandable to 48 I/O, real-time clock, micro-USB female connector, memory module compartment and Bluetooth adapter, push-in connection PLC logic expansion module with 16 I/Os for plug-in connection to 8 PLC-INTERFACE terminals for expansion of the basic module (maximum 2 expansion modules can be connected to one basic module), PLC logic basic module with RS-485 connection for Modbus/RTU communication, with 16 I/Os, for plug-in connection to 8 digital or analog PLC-INTERFACE terminal blocks, can be extended to 48 I/Os, real-time clock, micro USB female connector, accommodates memory module and Bluetooth adapter, Push-in connection

Automation > Logic module
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact part number PLC-V8C/PT-24DC/RS485 is a logic basic module intended to interface discrete signals with communication networks for distributed industrial control. Modular PLC architectures aggregate sensor inputs and actuator outputs for streamlined machine automation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Base unit
  • Product family: PLC logic
  • Operating mode: 100% operating factor
  • Insulation characteristics Insulation: Basic insulation
  • Overvoltage category: III
  • Pollution degree: 2
  • Rated surge voltage: 0.8 kV
  • Real-time clock Realtime clock: Yes
  • Buffer period: 96 h (Capacitor)
  • Accuracy realtime clock: ±2 s/d
  • Supply Supply voltage: 24 V DC
  • Supply voltage range: 19.2 V DC ... 26.4 V DC
  • Typical input current at U N: 40 mA
  • Maximum input current at U N: 160 mA
  • Protective circuit: Reverse polarity protection
  • Digital inputs Number of inputs: 8 (2 configurable as analog)

More info

▲
Technical data

Notes
GeneralFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Product properties
Product typeBase unit
Product familyPLC logic
Operating mode100% operating factor
Insulation characteristics
InsulationBasic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties
Air clearances and creepage distances between the power circuits
Rated insulation voltage50 V
Rated surge voltage0.8 kV
Real-time clock
Realtime clockYes
Buffer period96 h (Capacitor)
Accuracy realtime clock±2 s/d
Supply
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 26.4 V DC
Typical input current at UN40 mA
Maximum input current at UN160 mA
Protective circuitReverse polarity protection
Surge protection

Input data
Digital inputs
Number of inputs8 (2 configurable as analog)
Description of the inputEN 61131-2, type 3
Input voltage24 V DC
Signal level "0" signal< 5 V
Signal level "1" signal> 11 V
Input current "0" signal< 1 mA
Input current "1" signal2.5 mA
Status displayYellow LED
Analog inputs
Number of inputs2 (IN6 and IN7 are configurable as analog)
Input voltage range0 V ... 10 V
Input resistance> 3.5 kΩ
Contact to PLC-INTERFACE
Number of inputs≤ 8
Description of the inputtechnical data depends on the PLC-INTERFACE terminal block used
Input voltage19 V DC
Typical current consumption4 mA
Input resistance< 100 mΩ

Output data
Number of outputs≤ 8
Nominal output voltage24 V DC
Nominal current9 mA

Connection data
Cross section AWG(converted acc. to IEC)
COMBICON connection
Connection methodPush-in connection
Stripping length9 mm
Number of connections1
Number of positions10
NoteDevice supply and 8 x inputs
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.25 mm² ... 0.5 mm² (Ferrule with plastic sleeve)
0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Conductor cross section AWG26 ... 16
Programming connection
Connection methodMicro USB type B
Number of connections1
RS-485
Connection methodSpring-cage connection
Stripping length6 mm
Number of connections1
Number of positions3
Conductor cross section rigid0.14 mm² ... 0.5 mm²
Conductor cross section flexible0.2 mm² ... 0.5 mm²
Conductor cross section AWG26 ... 20
PLC logic - bus
Connection methodInsulation displacement connection
Number of connections1
Number of positions4
Memory
Connection methodS-PORT (socket)
Number of connections1
Number of positions12
NoteFor connecting the memory module

Interfaces
Data: RS-485
Data rate19200 Baud
Termination resistor150 Ω
Protocols supportedModbus/RTU

Signaling
Status displayGreen LED

Dimensions
Dimensional drawing
Width50 mm
Height48.5 mm
111 mm (with relay)
Depth82.5 mm
87 mm (with relay)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C
Max. permissible relative humidity (operation)95 %

Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178

Mounting
Mounting typePlug-in mounting
Assembly instructionscan be plugged onto 8 x PLC-INTERFACE terminal blocks
Mounting positionany

Product Datasheet