PLC-OPT- 24DC/TTL 2900363 PHOENIX CONTACT PLC solid-state relay with Push-in connection, for mounting on DIN..
PLC-OPT-24DC/TTL
2900363
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Featuring a Push-in connection for simple DIN rail mounting, the Phoenix Contact PLC-OPT-24DC/TTL PLC solid-state relay translates industrial control signals to TTL compatible levels. This type of interface is essential for mixed systems combining standard automation gear with logic level electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Output voltage (EF003933): 4.5 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 0.05 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 86 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Switching threshold "0" signal in reference to UN | < 0.4 |
| Switching threshold "1" signal in reference to UN | > 0.8 |
| Typical input current at UN | 3.4 mA |
| Typical response time | 35 µs |
| Typical turn-off time | 35 µs |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Parallel polarity protection diode |
| Surge voltage protection | > 33 V |
| Transmission frequency | 1 kHz |
Output data
| Designation | Output data |
|---|---|
| Output nominal voltage | 5 V DC -10 % ... +20 % |
| Limiting continuous current | A TTL load (Fan out = 1)/50 mA for switching mode |
| Fan out | 1 |
| Surge voltage protection | > 8 V |
| Voltage drop at max. limiting continuous current | < 80 mV |
| Output circuit | 3-conductor, ground-referenced |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Parallel polarity protection diode |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data, output side
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage input/output | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Rated insulation voltage | 250 V DC |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated insulation voltage | 250 V DC |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
eCl@ss
| eCl@ss 4.0 | 27371001 |
|---|---|
| eCl@ss 4.1 | 27371001 |
| eCl@ss 5.0 | 27371001 |
| eCl@ss 5.1 | 27371001 |
| eCl@ss 6.0 | 27371001 |
| eCl@ss 7.0 | 27371001 |
| eCl@ss 8.0 | 27371604 |
| eCl@ss 9.0 | 27371604 |
ETIM
| ETIM 4.0 | EC000196 |
|---|---|
| ETIM 5.0 | EC001504 |
UNSPSC
| UNSPSC 6.01 | 30211916 |
|---|---|
| UNSPSC 7.0901 | 39121542 |
| UNSPSC 11 | 39121542 |
| UNSPSC 12.01 | 39121542 |
| UNSPSC 13.2 | 39121542 |