View larger
PLC-OSC- 24DC/ 24DC/ 10/R 2982702 PHOENIX CONTACT Solid-state relay module
PLC-OSC-24DC/ 24DC/ 10/R
2982702
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for demanding switching applications, the Phoenix Contact PLC-OSC- 24DC/ 24DC/ 10/R solid-state relay module handles higher current loads without mechanical wear. These electronic modules are widely deployed in industrial control systems to couple PLC outputs with heavy-duty actuators.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Output voltage (EF003933): 8 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 10 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Key Commercial Data
| Orderkey | 2982702 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 407 (C-5-2017) |
| GTIN | 4046356155748 |
| Weight per Piece (excluding packing) | 38.020 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Input voltage range | 19.2 V DC ... 28.8 V DC |
| Switching threshold "0" signal in reference to UN | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 3 mA |
| Typical response time | 0.15 ms |
| Typical turn-off time | 1 ms |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Transmission frequency | 100 Hz |
| Power dissipation for nominal condition | 0.07 W |
Output data
| Designation | DC voltage output |
|---|---|
| Output voltage range | 5 V DC ... 33 V DC |
| Limiting continuous current | 10 A (see derating curve) |
| Maximum inrush current | 100 A (t = 20 ms) |
| Voltage drop at max. limiting continuous current | ≤ 50 mV |
| Output circuit | 3-conductor, ground-referenced |
| Type of protection | Protection against polarity reversal (not continuous protection) |
| Surge protection | |
| Designation | Alarm output |
| Output voltage range | 3 V DC ... 33 V DC (High active) |
| Limiting continuous current | 100 mA |
| Voltage drop at max. limiting continuous current | < 1.2 V |
| Indication | Red LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Suppressor diode |
Connection data 1
| Connection name | Input side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data 2
| Connection name | Output side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Rated insulation voltage | 300 V |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Rated insulation voltage | 300 V |
| Rated surge voltage | 4 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |