View larger
PLC-OPT-120UC/ 48DC/100/SEN 2900359 PHOENIX CONTACT PLC-INTERFACE for input functions, consisting of PLC-BPT..
PLC-OPT-120UC/ 48DC/100/SEN
2900359
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Tailored for sensor interface applications, the Phoenix Contact PLC-OPT-120UC/ 48DC/100/SEN 2900359 PHOENIX CONTACT PLC-INTERFACE for input functions, consisting of PLC-BPT.. module efficiently conditions and transfers incoming signals from field sensors to control units. Such interface blocks streamline DIN rail wiring and ensure noise-free signal transmission in automated machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 96 V
- Type of voltage (input voltage) (EF003033): AC
- Output voltage (EF003933): 3 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 0.1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 94 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Input data
| Nominal input voltage UN | 120 V AC (110 V DC) |
|---|---|
| 110 V DC | |
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Switching threshold "0" signal in reference to UN | ≤ 0.3 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 3.5 mA |
| Typical response time | 6 ms (at UN) |
| Typical turn-off time | 10 ms (at UN) |
| Operating voltage display | Yellow LED |
| Type of protection | Bridge rectifier |
| Protective circuit/component | Bridge rectifier |
| Transmission frequency | 10 Hz |
Output data
| Output voltage range | 3 V DC ... 48 V DC |
|---|---|
| Limiting continuous current | 100 mA |
| Voltage drop at max. limiting continuous current | ≤ 1 V |
| Output circuit | 2-wire, floating |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage input/output | 2.5 kV (50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated surge voltage/insulation | Basic insulation |
| Pollution degree | 2 |
| Overvoltage category | III |