View larger
PLC-RSC- 24DC/PMC T200/21HC 2307293 PHOENIX CONTACT Timer relay
PLC-RSC-24DC/PMC T200/21HC
2307293
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PLC-RSC- 24DC/PMC T200/21HC 2307293 PHOENIX CONTACT Timer relay is a specialized switching component designed to introduce time delays into control logic and automation sequences. Timer relays are commonly utilized in industrial panels to manage motor starting intervals, conveyor timing, and sequential process automation. Final pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Product family: PLC-INTERFACE
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 08.07.2024
- Article revision: 09
- Overvoltage category: III
- Pollution degree: 3
- Maximum power dissipation for nominal condition: 0.4 W
- Coil side Nominal input voltage U N: 24 V DC
- Input voltage range: 19.2 V DC ... 26.4 V DC (20 °C)
- Nominal voltage (plugged-in electromechanical relay): 24 V DC
- Typical input current at U N: 15 mA (Relay ON)
- Typical response time: 7 ms
- Typical release time: 200 ms +130 ms (Typical interval time at U N )
- Protective circuit: Surge protection
- Freewheeling diode:
More info
▲| Product type | Relay Module |
| Product family | PLC-INTERFACE |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 08.07.2024 |
| Article revision | 09 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Safe isolation, reinforced insulation (partition plate PLC-ATP should be installed for safe isolation between adjacent modules). |
| Overvoltage category | III |
| Pollution degree | 3 |
| Maximum power dissipation for nominal condition | 0.4 W |
| Coil side | |
| Nominal input voltage UN | 24 V DC |
| Input voltage range | 19.2 V DC ... 26.4 V DC (20 °C) |
| Nominal voltage (plugged-in electromechanical relay) | 24 V DC |
| Typical input current at UN | 15 mA (Relay ON) |
| 4.3 mA (Relay OFF) | |
| Typical response time | 7 ms |
| Typical release time | 200 ms +130 ms (Typical interval time at UN) |
| Protective circuit | Surge protection; Freewheeling diode |
| Operating voltage display | Yellow LED |
| Switching | |
| Contact switching type | Single contact, 1 changeover contact |
| Type of switch contact | Single contact |
| Contact material | AgNi, hard gold-plated |
| Maximum switching voltage | 250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.) |
| Minimum switching voltage | 12 V AC/DC |
| Limiting continuous current | 10 A |
| Maximum inrush current | 16 A |
| Min. switching current | 100 mA |
| Switching: when the gold layer is destroyed | |
| Interrupting rating (ohmic load) max. | 240 W (at 24 V DC) |
| 144 W (at 48 V DC) | |
| 48 W (at 60 V DC) | |
| 50 W (at 110 V DC) | |
| 80 W (at 220 V DC) | |
| 4000 W (for 250 V AC) | |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² (Single ferrule) | |
| 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) | |
| Conductor cross section AWG | 26 ... 14 |
| Tightening torque | 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing)) |
| Width | 14 mm |
| Height | 80 mm |
| Depth | 94 mm |
| Color | green (RAL 6021) |
| Flammability rating according to UL 94 | V0 (Housing) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| Air clearances and creepage distances | |
| Standards/regulations | DIN EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |