View larger
PLC-RSC-120UC/21HC/MS 2910517 PHOENIX CONTACT Relay Module
PLC-RSC-120UC/21HC/MS
2910517
PHOENIX CONTACT
1 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Relay Module combines switching elements and terminal connections to facilitate rapid installation and dependable circuit isolation in industrial automation setups. These pre-fabricated assemblies protect control electronics by safely managing high-voltage or high-current loads.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- Complete with socket (EF003359): Yes
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 96 V
- Rated control supply voltage AC 60 Hz (EF003979): 96 V
- Rated control supply voltage DC (EF003980): 93.5 V
- Voltage type for actuating (EF008242): AC
- Drive, polarization (EF003355): Polarized
- Drive, switching attitude (EF003356): Mono stable
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 1
- Type of switch contact (EF003358): Single contact
- With forced-guided contacts (EF003357): No
- Material of contact surface (EF004020): Untreated
More info
▲Key Commercial Data
| Orderkey | 2910517 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626487410 |
| Weight per Piece (excluding packing) | 67.000 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Coil side
| Nominal input voltage UN | 120 V AC |
|---|---|
| 110 V DC | |
| Typical input current at UN | 5 mA |
| Typical response time | 6 ms (110 V DC) |
| 3 ms ... 15 ms (120 V AC) | |
| Typical release time | 8 ms (110 V DC) |
| Typical release time range | 3 ms ... 15 ms (120 V AC) |
| Protective circuit | Bridge rectifier Bridge rectifier |
| Operating voltage display | Yellow LED |
Contact side
| Contact type | 1 PDT |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage | 12 V (10 mA) |
| Min. switching current | 10 mA (12 V) |
| Maximum inrush current | 24 A (20 ms) |
| Limiting continuous current | 10 A |
| Interrupting rating (ohmic load) max. | 264 W (24 V DC) |
| 62 W (48 V DC) | |
| 48 W (60 V DC) | |
| 52 W (110 V DC) | |
| 66 W (220 V DC) | |
| 2750 VA (250 V AC) | |
| Switching capacity | 2 A (24 V, DC13) |
| 3 A (230 V, AC15) |
Connection data input side
| Connection name | Coil side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1.5 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
Connection data output side
| Connection name | Contact side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1.5 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage relay winding/relay contact | 4 kVrms(50 Hz, 1 min.) |
|---|---|
| Test voltage PDT/PDT | 2.5 kVrms(50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Degree of protection | RT II (Relay) |
| IP20 (Relay base) | |
| Mechanical service life | 5x 106cycles |
| UL, USA | UL 508 |
| UL 508 Recognized | |
| UL, USA/Canada | cUL 508 |
| cUL 508 Recognized | |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
Standards and Regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | EN 50178 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation, reinforced insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
| UL, USA | UL 508 |
| UL 508 Recognized | |
| UL, USA/Canada | cUL 508 |
| cUL 508 Recognized |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |