View larger
PLC-RPT- 24DC/2X21/FG 2910537 PHOENIX CONTACT Relay Module
PLC-RPT-24DC/2X21/FG
2910537
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Relay Module PLC-RPT-24DC/2X21/FG by Phoenix Contact is engineered for safety-critical industrial loops requiring dependable signal switching and fault isolation. These modular interface units integrate smoothly into standard DIN rail configurations within control cabinets to manage interlocking tasks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Product family: PLC-INTERFACE
- Application: Forcibly guided contacts
- Operating mode: 100% operating factor
- Mechanical service life: approx. 10 7 cycles
- B 10d: 600000 Cycles (AC1; 250 V / 6 A; 1 NO)
- Data management status Date of last data management: 08.07.2024
- Article revision: 03
- Insulation characteristics: Standards/regulations Insulation: Safe isolation, reinforced insulation
- Overvoltage category: III
- Pollution degree: 2
- Maximum power dissipation for nominal condition: 0.72 W
- Test voltage (Winding/contact): 4 kV rms (50 Hz, 1 min., winding/contact)
- Test voltage (Changeover contact/changeover contact): 2.5 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
- Standards/regulations Rated insulation voltage: 250 V AC
- Rated surge voltage: 6 kV
More info
▲| Product type | Relay Module |
| Product family | PLC-INTERFACE |
| Application | Forcibly guided contacts |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 107cycles |
| B10d | 600000 Cycles (AC1; 250 V / 6 A; 1 NO) |
| 900000 Cycles (AC1; 250 V / 3 A; 1 NO) | |
| 1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO) | |
| 180000 Cycles (AC15; 250 V / 3 A; 1 NO) | |
| 560000 Cycles (AC15; 250 V / 2 A; 1 NO) | |
| 4600000 Cycles (AC15; 250 V / 0,75 A; 1 NO) | |
| 360000 Cycles (DC13; 24 V / 3 A; 1 NO) | |
| 740000 Cycles (DC13; 24 V / 1,5 A; 1 NO) | |
| 4200000 Cycles (DC13; 24 V / 0,75 A; 1 NO) | |
| Data management status | |
| Date of last data management | 08.07.2024 |
| Article revision | 03 |
| Insulation characteristics: Standards/regulations | |
| Insulation | Safe isolation, reinforced insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
| Maximum power dissipation for nominal condition | 0.72 W |
| Test voltage (Winding/contact) | 4 kVrms(50 Hz, 1 min., winding/contact) |
| Test voltage (Changeover contact/changeover contact) | 2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
| Standards/regulations | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Coil side | |
| Nominal input voltage UN | 24 V DC |
| Input voltage range | 20.2 V DC ... 32.4 V DC (20 °C) |
| Input voltage range in reference to UN | see diagram |
| Nominal voltage (plugged-in electromechanical relay) | 24 V DC |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 30 mA |
| Typical response time | 10 ms |
| Typical release time | 10 ms |
| Protective circuit | Freewheeling diode |
| Operating voltage display | Yellow LED |
| Switching | |
| Contact switching type | 2 changeover contacts, forcibly actuated |
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (10 mA) |
| Limiting continuous current | 6 A |
| Maximum inrush current | 6 A |
| Min. switching current | 10 mA (5 V) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC) |
| 288 W (48 V DC) | |
| 88 W (110 V DC) | |
| 110 W (220 V DC) | |
| 1500 VA (250 V AC) | |
| Switching capacity min. | 150 mW |
| Switching capacity | 3 A (24 V, DC13) |
| 3 A (230 V, AC15) | |
| Force-guided contacts in accordance with EN 61810-3 | Type B |
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² (Single ferrule) | |
| 2x 0.5 mm² ... 1 mm² (TWIN ferrule) | |
| Conductor cross section AWG | 26 ... 14 |
| Width | 14 mm |
| Height | 80 mm |
| Depth | 104 mm |
| Color | gray (RAL 7042) |
| Ambient conditions | |
| Degree of protection (Relay) | RT II (Relay) |
| Degree of protection (Relay base) | IP20 (Relay base) |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
| Altitude | ≤ 2000 m |
| CE | |
| Certificate | CE-compliant |
| UKCA | |
| Certificate | UKCA-compliant |
| UL, USA | |
| Identification | UL 508 |
| UL 508 Recognized | |
| UL, USA/Canada | |
| Identification | UL 508 |
| UL 508 Recognized | |
| Shipbuilding approval | |
| Certificate | TAE0000196 |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| DNV GL data | |
| Temperature | D |
| Humidity | A |
| Vibration | B/C |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Standards/regulations | |
| Standards/regulations | IEC 60947-5-1 |
| DIN EN 61810-3 | |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |