View larger
PLC-RPT- 24DC/21-21/MS 2910519 PHOENIX CONTACT Relay Module
PLC-RPT-24DC/21-21/MS
2910519
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PLC-RPT-24DC/21-21/MS is a Relay Module designed for DIN-rail mounting inside industrial control enclosures. It provides necessary electrical isolation and signal conditioning between central controllers and field instrumentation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2910519
- Packing unit: 10 pc
- GTIN: 4055626486710
- Weight per Piece (excluding packing): 64.000 g
- Custom tariff number: 85364190
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 14 mm
- Height: 80 mm
- Depth: 104 mm
- Ambient temperature (operation): -20 °C ... 60 °C
- Ambient temperature (storage/transport): -20 °C ... 85 °C
- Nominal input voltage U N: 24 V DC
- Typical input current at U N: 18 mA
- Typical response time: 10 ms
- Typical release time: 10 ms
More info
▲Key Commercial Data
| Orderkey | 2910519 |
|---|---|
| Packing unit | 10 pc |
| GTIN | 4055626486710 |
| Weight per Piece (excluding packing) | 64.000 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Coil side
| Nominal input voltage UN | 24 V DC |
|---|---|
| Typical input current at UN | 18 mA |
| Typical response time | 10 ms |
| Typical release time | 10 ms |
| Coil voltage | 24 V DC |
| Protective circuit | Free-wheeling diode Damping diode |
| Operating voltage display | Yellow LED |
Contact side
| Contact type | 2 PDT |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage | 12 V (10 mA) |
| Min. switching current | 10 mA (12 V) |
| Maximum inrush current | 12 A (20 ms) |
| Limiting continuous current | 6 A |
| Interrupting rating (ohmic load) max. | 192 W (24 V DC) |
| 62 W (48 V DC) | |
| 42 W (60 V DC) | |
| 55 W (110 V DC) | |
| 66 W (220 V DC) | |
| 2000 VA (250 V AC) | |
| Switching capacity | 1 A (24 V, DC13) |
| 1.5 A (230 V, AC15) |
Connection data input side
| Connection name | Coil side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
Connection data output side
| Connection name | Contact side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
|---|---|
| Test voltage PDT/PDT | 2.5 kV AC (50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Degree of protection | RT II (Relay) |
| IP20 (Relay base) | |
| Mechanical service life | 5x 106cycles |
| UL, USA | UL 508 |
| UL 508 Recognized | |
| UL, USA/Canada | cUL 508 |
| cUL 508 Recognized | |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
Standards and Regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | EN 50178 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation of input/output |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
| UL, USA | UL 508 |
| UL 508 Recognized | |
| UL, USA/Canada | cUL 508 |
| cUL 508 Recognized |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |