View larger
PLC-RPT- 12DC/ 1IC/ACT 1078801 PHOENIX CONTACT PLC-INTERFACE for high switch-on currents, consisting of PLC-..
PLC-RPT-12DC/ 1IC/ACT
1078801
PHOENIX CONTACT
1 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact PLC-INTERFACE relay module, part number PLC-RPT-12DC/ 1IC/ACT, is engineered specifically to handle demanding capacitive and high inrush loads typically encountered when switching actuators or lamps. Industrial control technicians rely on specialized interface relays to prevent contact welding and ensure long operating life under severe switching conditions.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Complete with socket (EF003359): Yes
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Rated control supply voltage DC (EF003980): 10.32 V
- Voltage type for actuating (EF008242): DC
- Drive, polarization (EF003355): Polarized
- Drive, switching attitude (EF003356): Mono stable
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as change-over contact (EF008257): 0
- Type of switch contact (EF003358): Single contact
- With forced-guided contacts (EF003357): No
- Material of contact surface (EF004020): Untreated
- Nominal current (EF000001): 0.033 A
- Degree of protection (IP) (EF005474): IP20
- Width (EF000008): 14 mm
More info
▲Key Commercial Data
| Orderkey | 1078801 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 382 (C-5-2019) |
| GTIN | 4055626796314 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|---|
| Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
| The PLC-ATP separating plate should be installed for safe isolation between adjacent modules | |
| The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. | |
| The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m |
| Degree of protection | RT II (Relay) |
| IP20 (Relay base) | |
| ≥ IP54 (Installation location) |
Coil side
| Nominal input voltage UN | 12 V DC |
|---|---|
| Typical input current at UN | 33 mA |
| Typical response time | 8 ms |
| Typical release time | 10 ms |
| Coil voltage | 12 V DC |
| Protective circuit | Reverse polarity protection Polarity protection diode |
| Free-wheeling diode Damping diode | |
| Operating voltage display | Yellow LED |
| Power dissipation for nominal condition | 0.4 W |
Contact side
| Contact type | 1 N/O contact |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage | 12 V (at 100 mA) |
| Min. switching current | 100 mA (at 12 V DC) |
| Maximum inrush current | 80 A (for 20 ms) |
| 130 A (peak, at capacitive load, 230 V AC, 24 μF) | |
| Limiting continuous current | 6 A |
| 10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged) | |
| Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
| 58 W (at 48 V DC) | |
| 48 W (at 60 V DC) | |
| 50 W (at 110 V DC) | |
| 80 W (at 220 V DC) | |
| 85 W (for 250 V DC) | |
| 1500 VA (for 250 V AC) | |
| Interrupting rating (ohmic load) max. bridged | 240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
| 2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) | |
| Switching capacity min. | 1200 mW |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.2 A (at 110 V, DC13) | |
| 0.2 A (at 250 V, DC13) | |
| 6 A (at 24 V, AC15) | |
| 6 A (at 120 V, AC15) | |
| 6 A (at 250 V, AC15) |
General
| Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
|---|---|
| Operating mode | 100% operating factor |
| Mechanical service life | 3x 107cycles |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
Connection data
| Connection name | Coil side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² (Single ferrule) | |
| 2x 0.5 mm² ... 1 mm² (TWIN ferrule) | |
| Conductor cross section AWG | 26 ... 14 |
Connection data 2
| Connection name | Contact side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² (Single ferrule) | |
| 2x 0.5 mm² ... 1 mm² (TWIN ferrule) | |
| Conductor cross section AWG | 26 ... 14 |
Standards and Regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | EN 50178 |
| EN 61810-1 | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation, reinforced insulation |
| Pollution degree | 2 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |