PHOENIX CONTACT PLC-OSC-24DC/ 24DC/ 3RW PLC-OSC- 24DC/ 24DC/ 3RW 2980610 PHOENIX CONTACT Solid-state relay module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-OSC- 24DC/ 24DC/ 3RW 2980610 PHOENIX CONTACT Solid-state relay module

PLC-OSC-24DC/ 24DC/ 3RW

2980610

PHOENIX CONTACT

1 Pcs.

Solid-state relay module PLC-INTERFACE for railway applications, consisting of screw terminal block and integrated miniature solid-state relay, range: 0.7 x UN to 1.25 x UN, temperature range: -25 °C to +70 °C, 1 closing contact, input: 24 V DC, output: 3-33 V DC/3 A

Automation > Optocoupler
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact PLC-OSC- 24DC/ 24DC/ 3RW is a solid-state relay module engineered specifically for demanding railway applications within the PLC-INTERFACE family. Solid-state interfaces provide vibration-resistant, silent switching for critical transport infrastructure and rolling stock control systems.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Solid-state relay module
  • Product family: PLC-INTERFACE
  • Application: Railway applications
  • Data management status Date of last data management: 16.09.2024
  • Article revision: 08
  • Pollution degree: 2
  • Maximum power dissipation for nominal condition: 0.2 W
  • Nominal input voltage U N: 24 V DC
  • Input voltage range in reference to U N: 0.7 ... 1.25
  • Input voltage range: 16.8 V DC ... 30 V DC
  • Switching threshold "0" signal in reference to U N: ≤ 0.3
  • Switching threshold "1" signal in reference to U N: ≥ 0.6
  • Typical input current at U N: 8.5 mA
  • Typical response time: 40 µs
  • Typical turn-off time: 200 µs
  • Status display: LED (yellow)

More info

▲
Technical data

Product properties
Product typeSolid-state relay module
Product familyPLC-INTERFACE
ApplicationRailway applications
Data management status
Date of last data management16.09.2024
Article revision08
Insulation characteristics: Standards/regulations
Overvoltage categoryIII
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition0.2 W

Input data
Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.7 ... 1.25
Input voltage range16.8 V DC ... 30 V DC
Switching threshold "0" signal in reference to UN≤ 0.3
Switching threshold "1" signal in reference to UN≥ 0.6
Typical input current at UN8.5 mA
Typical response time40 µs
Typical turn-off time200 µs
Status displayLED (yellow)
Protective circuitReverse polarity protection; Polarity protection diode
Transmission frequency300 Hz

Output data
Contact switching type1 N/O contact
Design of digital outputelectronic
Output voltage range3 V DC ... 33 V DC
Limiting continuous current3 A
Voltage drop at max. limiting continuous current≤ 200 mV
Output circuit2-conductor, floating
Protective circuitReverse polarity protection; Polarity protection diode
Surge protection

Connection data
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))

Dimensions
Width6.2 mm
Height80 mm
Depth94 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Approvals
CE
CertificateCE-compliant
UKCA
CertificateUKCA-compliant
Shipbuilding approval
CertificateTAE0000196
Corrosive gas test
IdentificationISA-S71.04. G3 Harsh Group
EN 60068-2-60
DNV GL data
TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC directive
Low Voltage DirectiveConformance with Low Voltage Directive

Standards and regulations
Standards/regulations
Standards/regulationsIEC 60947-5-1
DIN EN 50155/VDE 0115-200 (in relevant parts)

Mounting
Mounting typeDIN rail mounting
Assembly notein rows with zero spacing
Mounting positionany

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.