View larger
PLC-OPT-125DC/300DC/1 2900390 PHOENIX CONTACT Solid-state relay module
PLC-OPT-125DC/300DC/1
2900390
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Enabling seamless voltage adaptation, the Phoenix Contact PLC-OPT-125DC/300DC/1 solid-state relay module protects automation networks by isolating control logic from field loads. Electronic coupling devices are standard in modern switchgear to manage discrete signals safely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 100 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 12 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): No
More info
▲Key Commercial Data
| Orderkey | 2900390 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356508933 |
| Weight per Piece (excluding packing) | 31.000 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Input data
| Nominal input voltage UN | 125 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Input voltage range | 100 V DC ... 138 V DC |
| Typical input current at UN | 6 mA |
| Transmission frequency | 50 Hz |
| Power dissipation for nominal condition | 0.75 W |
Output data
| Designation | Output data |
|---|---|
| Output voltage range | 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Limiting continuous current | 1 A (see derating curve) |
| Voltage drop at max. limiting continuous current | < 500 mV |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data, output side
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Rated insulation voltage | 300 V |
| Rated surge voltage | 4 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |