View larger
PLC-V8C/PT-24DC/EM 2905137 PHOENIX CONTACT Extension module
PLC-V8C/PT-24DC/EM
2905137
PHOENIX CONTACT
1 Pcs.
Automation > Logic module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact extension module, designated as PLC-V8C/PT-24DC/EM, is an auxiliary device utilized in automation panels to expand signal processing capacity and channel count. These modules integrate into existing control frameworks to manage mixed analog and digital signal routing efficiently across complex machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 0.009 A
- Number of analogue inputs (EF001994): 2
- Number of analogue outputs (EF001995): 8
- Number of digital inputs (EF001992): 8
- Number of digital outputs (EF001993): 8
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces USB (EF003025): 0
- Number of HW-interfaces parallel (EF003026): 0
More info
▲Key Commercial Data
| Orderkey | 2905137 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 429 (C-5-2017) |
| GTIN | 4046356919487 |
| Weight per Piece (excluding packing) | 121.200 g |
| Custom tariff number | 85389099 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Power supply
| Supply voltage | 24 V DC |
|---|---|
| Supply voltage range | 19.2 V DC ... 26.4 V DC |
| Maximum input current at UN | 65 mA |
| Protective circuit | Reverse polarity protection |
| Surge protection | |
| Status display | Green LED |
Input data (digital)
| Number of inputs | 8 (2 configurable as analog) |
|---|---|
| Description of the input | EN 61131-2, type 3 |
| Input voltage | 24 V DC |
| Signal level "0" signal | < 5 V |
| Signal level "1" signal | > 11 V |
| Input current "0" signal | < 1 mA |
| Input current "1" signal | typ. 2.5 mA |
| Status display | Yellow LED |
Input data (analog)
| Number of inputs | 2 (IN6 and IN7 are configurable as analog) |
|---|---|
| Input voltage range | 0 V ... 10 V |
| Input resistance | > 3.5 kΩ |
Input data (PLC-INTERFACE)
| Number of inputs | ≤ 8 |
|---|---|
| Description of the input | technical data depends on the PLC-INTERFACE terminal block used |
| Input voltage | 19 V DC |
| Typical current consumption | 4 mA |
| Input resistance | < 100 mΩ |
General
| Color | gray |
|---|---|
| Mounting position | any |
| Assembly instructions | can be plugged onto 8 x PLC-INTERFACE terminal blocks |
| Operating mode | 100% operating factor |
| Degree of protection | IP20 |
Connection data (supply and digital inputs)
| Connection method | Push-in connection |
|---|---|
| Stripping length | 9 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.25 mm² ... 0.5 mm² (Ferrule with plastic sleeve) | |
| 0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve) | |
| Conductor cross section AWG | 26 ... 16 |
| Number of connections | 1 |
| Number of positions | 10 |
| Note | Device supply and 8 x inputs |
Connection data (PLC V8C bus)
| Connection method | Insulation displacement connection |
|---|---|
| Number of connections | 1 |
| Number of positions | 4 |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 45 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 95 % |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.8 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |