View larger
PLC-OSC-220DC/300DC/ 1 2980704 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with screw conne..
PLC-OSC-220DC/300DC/ 1
2980704
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing dependable signal conversion for high-voltage DC systems, the Phoenix Contact PLC-OSC-220DC/300DC/ 1 solid-state relay module features an integrated interface design. Panel builders use these components to protect control hardware and safely execute frequent switching operations without contact erosion. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 176 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 12 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 86 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Input data
| Nominal input voltage UN | 220 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Switching threshold "0" signal in reference to UN | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 3 mA |
| Typical response time | 0.4 ms |
| Typical turn-off time | 1.4 ms |
| Operating voltage display | Yellow LED |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor | |
| Transmission frequency | 50 Hz |
Output data
| Designation | Output data |
|---|---|
| Output voltage range | 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Limiting continuous current | 1 A (see derating curve) |
| Voltage drop at max. limiting continuous current | < 500 mV |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Rated insulation voltage | 300 V |
| Pollution degree | 2 |
| Overvoltage category | III |