View larger
PLC-OSC-120AC/300DC/ 1 2980717 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with screw conne..
PLC-OSC-120AC/300DC/ 1
2980717
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact provides the PLC-OSC-120AC/300DC/ 1 2980717 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with screw conne.., which functions as a robust solid-state relay interface module for industrial switching tasks. Technicians use these components to bridge low-level controller outputs with higher-voltage field actuators while maintaining complete circuit isolation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 96 V
- Type of voltage (input voltage) (EF003033): AC
- Output voltage (EF003933): 12 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 86 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Input data
| Nominal input voltage UN | 120 V AC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Switching threshold "0" signal in reference to UN | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 5.6 mA |
| Typical response time | 19 ms |
| Typical turn-off time | 6 ms |
| Operating voltage display | Yellow LED |
| Type of protection | Bridge rectifier |
| Protective circuit/component | Bridge rectifier |
| Transmission frequency | 10 Hz |
Output data
| Designation | Output data |
|---|---|
| Output voltage range | 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Limiting continuous current | 1 A (see derating curve) |
| Voltage drop at max. limiting continuous current | < 500 mV |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Rated insulation voltage | 300 V |
| Pollution degree | 2 |
| Overvoltage category | III |