PLC-OPT-220DC/300DC/1 2900387 PHOENIX CONTACT PLC-INTERFACE, integrated solid-state relay, with Push-in conn..
PLC-OPT-220DC/300DC/1
2900387
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PLC-OPT-220DC/300DC/1 is a PLC-INTERFACE with an integrated solid-state relay and Push-in connections. Solid-state relays are utilized in industrial automation systems for switching electrical loads without mechanical wear, providing fast and reliable electronic signal isolation between control systems and field devices.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 176 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 12 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 86 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Input data
| Nominal input voltage UN | 220 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Input voltage range | 176 V DC ... 264 V DC |
| Switching threshold "0" signal in reference to UN | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 5.6 mA |
| Typical response time | 0.4 ms |
| Typical turn-off time | 1.4 ms |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor | |
| Transmission frequency | 50 Hz |
Output data
| Designation | Output data |
|---|---|
| Output voltage range | 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Limiting continuous current | 1 A (see derating curve) |
| Voltage drop at max. limiting continuous current | < 500 mV |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data, output side
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Rated insulation voltage | 300 V |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| IEC 62103 | |
| Rated insulation voltage | 300 V |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
eCl@ss
| eCl@ss 4.0 | 27371102 |
|---|---|
| eCl@ss 4.1 | 27371102 |
| eCl@ss 5.0 | 27371001 |
| eCl@ss 5.1 | 27371001 |
| eCl@ss 6.0 | 27371001 |
| eCl@ss 7.0 | 27371001 |
| eCl@ss 8.0 | 27371604 |
| eCl@ss 9.0 | 27371604 |
ETIM
| ETIM 2.0 | EC001504 |
|---|---|
| ETIM 3.0 | EC001504 |
| ETIM 4.0 | EC000196 |
| ETIM 5.0 | EC001504 |
UNSPSC
| UNSPSC 6.01 | 30211916 |
|---|---|
| UNSPSC 7.0901 | 39121542 |
| UNSPSC 11 | 39121542 |
| UNSPSC 12.01 | 39121542 |
| UNSPSC 13.2 | 39121542 |