View larger
PLC-HPT-24DC/230AC/10 2905215 PHOENIX CONTACT Solid-state relays
PLC-HPT-24DC/230AC/10
2905215
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The PLC-HPT-24DC/230AC/10 2905215 PHOENIX CONTACT Solid-state relays provide robust electronic switching capabilities, bridging low-power controller outputs with AC-driven industrial loads. Devices of this construction offer maintenance-free operation and high switching frequencies for demanding automation applications.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2905215
- Packing unit: 1 pc
- Catalog page: Page 409 (C-5-2017)
- GTIN: 4046356927307
- Weight per Piece (excluding packing): 63.060 g
- Custom tariff number: 85364190
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 14 mm
- Height: 80 mm
- Depth: 94 mm
- Ambient temperature (operation): -25 °C ... 60 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Degree of protection: IP20
- Rated control circuit supply voltage U S: 24 V DC
- Input voltage range: 19.2 V DC ... 28.8 V DC
More info
▲Key Commercial Data
| Orderkey | 2905215 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 409 (C-5-2017) |
| GTIN | 4046356927307 |
| Weight per Piece (excluding packing) | 63.060 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Rated control circuit supply voltage US | 24 V DC |
|---|---|
| Input voltage range | 19.2 V DC ... 28.8 V DC |
| Rated control supply current IS | 14 mA (Input low, output low) |
| 19 mA (Input high, output high) | |
| Rated actuating voltage UC | 24 V DC |
| "0" signal switching threshold in reference to UC | < 0.4 |
| "1" signal switching threshold in reference to UC | > 0.8 |
| Typical response time | 30 ms |
| Typical turn-off time | 20 ms |
| Status display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Surge voltage protection | > 33 V DC |
| Transmission frequency | 1 Hz |
| Power dissipation for nominal condition | 0.16 W |
Output data
| Designation | AC hybrid output |
|---|---|
| Output voltage range | 24 V AC ... 253 V AC (50/60 Hz) |
| Limiting continuous current | 10 A (see derating curve) |
| Min. load current | 100 mA |
| Leakage current | < 1 mA |
| Surge current | 250 A (tp = 20 ms, at 25°C) |
| Max. load value | 350 A2s (tp = 10 ms, at 25 °C) |
| Surge voltage protection | > 275 V |
| Output circuit | 2-wire, floating |
| Type of protection | RCV circuit |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data, output side
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Mounting position | any |
|---|---|
| Assembly instructions | See derating curve |
| Operating mode | 100% operating factor |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | DIN EN 50178 |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 260 V AC |
| Rated surge voltage | 6 kV |
| Insulation | safe isolation |
| Degree of pollution | 2 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |