Interface converters Second generation FL COMSERVER BASIC..., serial server for conversion of a serial RS-232/422/485 interface to Ethernet, supports TCP and UDP applications, incl. Com Port Redirector software and user documentation (PDF)

Automation > PLC communication module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact interface converters device, identified by part number FL COMSERVER BASIC 232/422/485, serves as a network communication server for connecting serial automation devices to IP-based infrastructures. Industrial setups use units of this type to extend the operational reach of field instruments and enable remote supervision over standard Ethernet architectures. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0
  • Number of HW-interfaces USB (EF003025): 0
  • Number of HW-interfaces parallel (EF003026): 0
  • Number of HW-interfaces wireless (EF006933): 0
  • Number of HW-interfaces other (EF003027): 0
  • With optical interface (EF003028): No
  • Supporting protocol for EtherCAT (EF017564): No
  • Supporting protocol for TCP/IP (EF003050): Yes
  • Supporting protocol for PROFIBUS (EF003052): No
  • Supporting protocol for CAN (EF003053): No
  • Supporting protocol for INTERBUS (EF003054): No

More info

▲

Key Commercial Data

Orderkey2313478
Packing unit1 pc
Catalog pagePage 341 (C-6-2017)
GTIN4046356451314
Weight per Piece (excluding packing)180.300 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width22.5 mm
Height99 mm
Depth116 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
-20 °C ... 60 °C (With UL approval)
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Electrical isolationDIN EN 50178 (VCC // Ethernet // Serial)
Test voltage data interface/data interface1.5 kVrms(50 Hz, 1 min.)
Test voltage data interface/power supply1.5 kVrms
1.5 kVrms(50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 61000-6-4
Net weight180.3 g
Housing materialPA 6.6-FR
Colorgreen
MTBF666 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
179 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF2001 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
870 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
355 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USAClass I, Zone 2, AEx nA IIC T5
UL, USA/Canada508 Listed
Class I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, zone 2, Ex nA IIC T5 Gc X

Power supply

Nominal supply voltage24 V AC/DC ±20 % (via pluggable COMBICON screw terminal block)
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
Supply voltage range19.2 V AC/DC ... 28.8 V AC/DC (via pluggable COMBICON screw terminal block)
22.8 V DC ... 25.2 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption100 mA (24 V DC)

Serial interface

Interface 1Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u
InterfaceEthernet
No. of ports1
Connection methodRJ45 socket, shielded
Transmission length≤ 100 m (shielded twisted pair)
Protocols supportedTCP/IP, UDP
Auxiliary protocolsARP, DHCP, BOOTP, SNMP, RIP, RARP, HTTP, TFTP, ICMP
Serial transmission speed10/100 Mbps, auto negotiation
Interface 2V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
InterfaceRS-232
Connection methodD-SUB 9 plug
File format/codingUART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Transmission length15 m
Pin assignmentDTE/DCE switchover via web-based management
Data flow control/protocolsSoftware handshake, Xon/Xoff or hardware handshake RTS/CTS
Serial transmission speed0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4 kbps
Interface 3RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
InterfaceRS-422
Connection methodPlug-in/screw connection via COMBICON
File format/codingUART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Transmission length≤ 1200 m
Termination resistor390 Ω (configurable)
180 Ω
390 Ω
Data flow control/protocolsAutomatic control
Serial transmission speed0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps
Interface 4RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
InterfaceRS-485
Connection methodPlug-in/screw connection via COMBICON
File format/codingUART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Termination resistor390 Ω (configurable)
180 Ω
390 Ω
Data flow control/protocolsAutomatic control
Serial transmission speed0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps

Function

Web-based managementyes
ManagementWeb-based management, SNMP, emergency exit with Telnet and serial
Status and diagnostic indicatorsLEDs: UL (logic voltage), TD + RD (data activity serial), FD (full duplex), 100 (100 Mbps mode), Link (Ethernet), Activity (Ethernet), ERR (error)

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testFree fall in acc. with IEC 60068-2-32
Test result1 m
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result15g, 11 ms period, half-sine shock pulse
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result30g, 11 ms period, half-sine shock pulse
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2:2005
Free from substances that could impair the application of coatingaccording to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Standards/regulationsEN 50121-4
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USAClass I, Zone 2, AEx nA IIC T5
UL, USA/Canada508 Listed
Class I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, zone 2, Ex nA IIC T5 Gc X
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50