View larger
SSL 2,5 3043815 PHOENIX CONTACT Panel feed-through
SSL 2,5
3043815
PHOENIX CONTACT
50 Pcs.
Automation > Installation clamp for meters
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Facilitating secure cable transitions through enclosure walls, the Phoenix Contact SSL 2,5 panel feed-through ensures insulated separation in demanding industrial environments. Feed-through components are widely used to pass conductors safely through metallic barriers while maintaining ingress protection.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Mounting material
- Data management status Article revision: 02
- Insulation characteristics Overvoltage category: III
- Rated surge voltage: 8.00 kV
- Width: 5.2 mm
- Plate thickness: 0.8 mm ... 3 mm
- Installation dimensions Length of the assembly cutout: 16.6 mm
- Color: gray (RAL 7042)
- Material: PA
- Flammability rating according to UL 94: V0
- Insulating material group: I
- Insulating material: PA
- Static insulating material application in cold: -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
More info
▲| Product type | Mounting material |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Overvoltage category | III |
| Rated surge voltage | 8.00 kV |
| Dimensional drawing | |
| Width | 5.2 mm |
| Plate thickness | 0.8 mm ... 3 mm |
| Installation dimensions | |
| Length of the assembly cutout | 16.6 mm |
| Color | gray (RAL 7042) |
| Material | PA |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |