PHOENIX CONTACT PACT SPC-20-1A-D13 PACT SPC-20-1A-D13 1382378 PHOENIX CONTACT Split Core Current Transformers, Primary Current: 20 A AC, Second.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PACT SPC-20-1A-D13 1382378 PHOENIX CONTACT Split Core Current Transformers, Primary Current: 20 A AC, Second..

PACT SPC-20-1A-D13

1382378

PHOENIX CONTACT

1 Pcs.

Split Core Current Transformers, Primary Current: 20 A AC, Secondary Current: 0 ... 1 A AC, Accuracy class: 3, rated power: 0.2 VA, signal line length: 2 m Split-core current transformer, primary current: 0 ... 20 A AC, secondary current: 0 ... 1 A AC, rated power: 0.2 VA, length of signal cable: 2 m

Automation > Current transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact part PACT SPC-20-1A-D13 (1382378) is a split-core current transformer engineered for retrofit applications where primary circuit disconnection is impractical. Split-core designs enable technicians to clamp the sensor directly around existing conductors for non-invasive current measurement.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Current transformer
  • Test voltage: 3 kV (EN 61869-1)
  • Rated insulation voltage: 0.72 kV
  • Measuring coil Length of signal cable: 2 m
  • General Converter type: Split-core current transformer
  • Current transformers Rated power: 0.2 VA
  • Thermal rated short-time current: I th = 60 * I n
  • Thermal rated continuous current: I d = 1.2 * I n
  • Rated surge current: I dyn = 2.5 * I th
  • Rated frequency f n: 50 Hz
  • Primary rated current range: 0 A AC ... 20 A AC (depends on type)
  • Converter type: Split-core current transformer
  • Signal Designation: Current output
  • Secondary rated current range I sn: 0 A AC ... 1 A AC
  • Surge current limitation factor: FS 5
  • Accuracy class: 3

More info

▲
Technical data

Product properties
Product typeCurrent transformer

Electrical properties
Test voltage3 kV (EN 61869-1)
Rated insulation voltage0.72 kV
Measuring coil
Length of signal cable2 m
General
Converter typeSplit-core current transformer

Input data
Current transformers
Rated power0.2 VA
Thermal rated short-time currentIth= 60 * In
Thermal rated continuous currentId= 1.2 * In
Rated surge currentIdyn= 2.5 * Ith
Rated frequency fn50 Hz
60 Hz
Primary rated current range0 A AC ... 20 A AC (depends on type)
Converter typeSplit-core current transformer

Output data
Signal
DesignationCurrent output
Secondary rated current range Isn0 A AC ... 1 A AC
Surge current limitation factorFS 5
Accuracy class3

Connection data
Cross section AWG(converted acc. to IEC)
Secondary connection
Connection methodSingle wires

Dimensions
Item dimensions
Width73 mm
Height35 mm
Depth22 mm
Circular conductor
Diameter13 mm (Inner hole)
Signal line
Length2 m
Width73 mm
Height35 mm
Depth22 mm
Primary round conductor (diameter)13 mm

Material specifications
Flammability rating according to UL 94V0
Housing materialPC

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 65 °C
Ambient temperature (storage/transport)-45 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)Use only indoors, non-condensing

Standards and regulations
Standards/regulationsIEC 61010-1
IEC 61010-2-032
IEC 61869-1
IEC 61869-2

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.