PHOENIX CONTACT PACT RCP-D140-10M PACT RCP-D140-10M 1033482 PHOENIX CONTACT Coil PACT RCP-D140-10M 1033482 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PACT RCP-D140-10M 1033482 PHOENIX CONTACT Coil PACT RCP-D140-10M 1033482

PACT RCP-D140-10M

1033482

PHOENIX CONTACT

1 Pcs.

Coil - PACT RCP-D140-10M - 1033482 Rogowski Coil, The Rogowski coil measures AC current from rails and high-voltage lines.

Automation > Accessories/spare parts for low-voltage switch technology
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

PACT RCP-D140-10M 1033482 PHOENIX CONTACT Coil PACT RCP-D140-10M 1033482 acts as a flexible Rogowski coil current sensor utilized for AC current measurement and power monitoring. Such Rogowski coils wrap easily around conductors in retrofit energy management and power metering installations.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Accessory (EF013236): Yes
  • Spare part (EF013237): No

More info

▲

Coil Rogowski, length of coil Rogowski: 450 mm, diameter: 140 mm, length of the signal cable: 10000 mm coil Rogowski measures the AC current of lanes and high-voltage lines.

Data commercial

Key orderOne million thirty three thousand four hundred eighty two
Packing unit1 pcs
Key sellingCK4A12 -
EANFour trillion fifty five billion six hundred twenty six million five hundred thirty nine thousand forty one
Unit weight (excluding packaging)372,400 g
Tariff number tariffNinety million three hundred nine thousand

Environmental conditions

Room temperature (service)-30 °C ... 80 °C (Coil of measure)
Ambient temperature (storage / transport)-40 °C ... 80 °C (Coil of measure)
Max. Height of fixing< 2000 m
Humidity of air permissible (service)5 % ... 95 % (without condensation)
Degree of protection of the coil measuringIP67 (not evaluated by UL)

Data input coil measurement

Range of measurement of frequency40 Hz ... 20000 Hz
Position Error< 1 %
Linearity Error0,1 %

Signals output coil measurement

Output signal (at 50 Hz)100 mV (no load, with 1000 (A)
Output voltage (at idle)VOUT= M * dI/dt
Output voltage (sinusoidal, running on empty)100 mV (VOUT= 2 * π * M * f * I (M = 0,318 µH; example: for 50 Hz, I = 1000))

General data coil measurement

Length of the coil measuring450 mm
Diameter of the coil measuring8.3 mm ±0.2 mm
Length of the line signals10000 mm
Construction of the driver signal cable2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielded (tinned))
Material of the coilElastollan
Material housingPC
IsolationDouble insulation
Isolation voltage design1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage10,45 kV DC / 1 min.)
Basic accuracy
UL, USA / CanadaUL 61010 Recognized

General data

Standards/specificationsIEC 61010-1
IEC 61010-2-032

Standards and specifications

Standards/specificationsIEC 61010-1
IEC 61010-2-032
UL, USA / CanadaUL 61010 Recognized

Environmental Product Compliance

China RoHSSpace of time for the intended use (FEUP): 50 years
You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab

Ratings

eCl@ss

eCl@ss 10.0.1Twenty seven million two hundred nineteen thousand two hundred ninety
eCl@ss 9.0Twenty seven million two hundred nineteen thousand two hundred ninety

Product Datasheet