Request QuoteProduct Overview
PACT RCP-D140-10M 1033482 PHOENIX CONTACT Coil PACT RCP-D140-10M 1033482 acts as a flexible Rogowski coil current sensor utilized for AC current measurement and power monitoring. Such Rogowski coils wrap easily around conductors in retrofit energy management and power metering installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Accessory (EF013236): Yes
- Spare part (EF013237): No
More info
▲Coil Rogowski, length of coil Rogowski: 450 mm, diameter: 140 mm, length of the signal cable: 10000 mm coil Rogowski measures the AC current of lanes and high-voltage lines.
Data commercial
| Key order | One million thirty three thousand four hundred eighty two |
|---|---|
| Packing unit | 1 pcs |
| Key selling | CK4A12 - |
| EAN | Four trillion fifty five billion six hundred twenty six million five hundred thirty nine thousand forty one |
| Unit weight (excluding packaging) | 372,400 g |
| Tariff number tariff | Ninety million three hundred nine thousand |
Environmental conditions
| Room temperature (service) | -30 °C ... 80 °C (Coil of measure) |
|---|---|
| Ambient temperature (storage / transport) | -40 °C ... 80 °C (Coil of measure) |
| Max. Height of fixing | < 2000 m |
| Humidity of air permissible (service) | 5 % ... 95 % (without condensation) |
| Degree of protection of the coil measuring | IP67 (not evaluated by UL) |
Data input coil measurement
| Range of measurement of frequency | 40 Hz ... 20000 Hz |
|---|---|
| Position Error | < 1 % |
| Linearity Error | 0,1 % |
Signals output coil measurement
| Output signal (at 50 Hz) | 100 mV (no load, with 1000 (A) |
|---|---|
| Output voltage (at idle) | VOUT= M * dI/dt |
| Output voltage (sinusoidal, running on empty) | 100 mV (VOUT= 2 * π * M * f * I (M = 0,318 µH; example: for 50 Hz, I = 1000)) |
General data coil measurement
| Length of the coil measuring | 450 mm |
|---|---|
| Diameter of the coil measuring | 8.3 mm ±0.2 mm |
| Length of the line signals | 10000 mm |
| Construction of the driver signal cable | 2x 0.22 mm (Signal (tinned)) |
| 1x 0.22 mm (Shielded (tinned)) | |
| Material of the coil | Elastollan |
| Material housing | PC |
| Isolation | Double insulation |
| Isolation voltage design | 1000 V AC (rms CAT III) |
| 600 V AC (rms CAT IV) | |
| Test voltage | 10,45 kV DC / 1 min.) |
| Basic accuracy | |
| UL, USA / Canada | UL 61010 Recognized |
General data
| Standards/specifications | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 |
Standards and specifications
| Standards/specifications | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| UL, USA / Canada | UL 61010 Recognized |
Environmental Product Compliance
| China RoHS | Space of time for the intended use (FEUP): 50 years |
|---|---|
| You will find information about hazardous substances in the manufacturer's declaration in the "Downloads"tab |
Ratings
eCl@ss
| eCl@ss 10.0.1 | Twenty seven million two hundred nineteen thousand two hundred ninety |
|---|---|
| eCl@ss 9.0 | Twenty seven million two hundred nineteen thousand two hundred ninety |