PACT RCP-4000A-1A-D190-3M-UV 1033485 PHOENIX CONTACT Current transformer
PACT RCP-4000A-1A-D190-3M-UV
1033485
PHOENIX CONTACT
1 Pcs.
Automation > Current transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-current monitoring, the PACT RCP-4000A-1A-D190-3M-UV 1033485 Phoenix Contact current transformer measures heavy alternating electrical currents in power systems. Flexible Rogowski sensors simplify retrofitting around existing busbars and cables within industrial installations. Product specifications and ordering identifiers are outlined below.
- Orderkey: 1033485
- Packing unit: 1 pc
- GTIN: 4055626538761
- Weight per Piece (excluding packing): 440.300 g
- Custom tariff number: 85437090
- Country of origin: DE (Germany)
- Nominal supply voltage: 24 V DC -20 % ... +25 %
- Nominal supply voltage range: 19.2 V DC ... 30 V DC
- Max. current consumption: 190 mA
- Power consumption: 4 W
- Frequency measuring range: 40 Hz ... 20000 Hz
- Position error: < 1 %
- Linearity error: 0.1 %
- Measuring ranges (current): 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
- Configurable/programmable: Via DIP switches
- Phase angle: < 1 °
Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
More info
▲Key Commercial Data
| Orderkey | 1033485 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626538761 |
| Weight per Piece (excluding packing) | 440.300 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
Measuring transducer supply
| Nominal supply voltage | 24 V DC -20 % ... +25 % |
|---|---|
| Nominal supply voltage range | 19.2 V DC ... 30 V DC |
| Max. current consumption | 190 mA |
| Power consumption | 4 W |
Measuring coil input data
| Frequency measuring range | 40 Hz ... 20000 Hz |
|---|---|
| Position error | < 1 % |
| Linearity error | 0.1 % |
Measuring transducer input data
| Measuring ranges (current) | 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A |
|---|---|
| Configurable/programmable | Via DIP switches |
| Phase angle | < 1 ° |
| Rated power | 1.5 VA |
| Max. distances for copper cables at PN max | 32 m (0.75 mm² (AWG 20)) |
| 64 m (1.5 mm² (AWG 16)) | |
| 107 m (2.5 mm² (AWG 14)) |
Measuring transducer signal input
| Input signal (at 50 Hz) | 100 mV (1000 A) |
|---|---|
| Input impedance | 27 kΩ (smallest measuring range) |
Measuring coil signal output
| Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
|---|---|
| Output voltage (in no-load operation) | VOUT= M * dI/dt |
| Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A)) |
General data, measuring coil
| Length of measuring coil | 600 mm |
|---|---|
| Diameter of measuring coil | 8.3 mm ±0.2 mm |
| Length of signal cable | 3000 mm |
| Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) |
| 1x 0.22 mm (Shielding (tinned)) | |
| Coil material | Elastollan |
| Housing material | PC |
| Insulation | double insulation |
| Rated insulation voltage | 1000 V AC (rms CAT III) |
| 600 V AC (rms CAT IV) | |
| Test voltage | 10.45 kV (DC / 1 min.) |
| Basic accuracy |
General data for measuring transducer
| Linearity error | < 0.5 % (From the range end value) |
|---|---|
| Maximum transmission error | ≤ 0.5 % (From the range end value) |
| Frequency range | 45 Hz ... 65 Hz |
| Max. detectable harmonics | < 2 kHz |
| Current consumption | < 190 mA (at 19.2 V) |
| Housing material | Polyamide |
| Test voltage | 1.5 kV AC (Supply/input and output: 50 Hz, 1 min) |
| Operating voltage display | Green LED |
| UL, USA/Canada | UL 508 Listed |
General data
| Standards/regulations | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| Insulation | double insulation |
| Degree of pollution | 2 |
| Overvoltage category | III (1,000 V, to neutral conductor) |
| IV (600 V, to neutral conductor) | |
| Temperature coefficients | 0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature) |
| 0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature) | |
| Typical measuring error | < 1 % |
Connection data
| Connection name | Measuring transducer side |
|---|---|
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Screw thread | M3 |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Torque | 0.5 Nm ... 0.6 Nm |
Ambient conditions
| Ambient temperature (operation) | -30 °C ... 80 °C (Measuring coil) |
|---|---|
| -20 °C ... 70 °C (Measuring transducer) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C (Measuring coil) |
| -25 °C ... 85 °C (Measuring transducer) | |
| Maximum altitude | < 2000 m |
| Measuring coil degree of protection | IP67 (not assessed by UL) |
| Measuring transducer degree of protection | IP20 |
Standards and Regulations
| Standards/regulations | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| Insulation | double insulation |
| Degree of pollution | 2 |
| Overvoltage category | III (1,000 V, to neutral conductor) |
| IV (600 V, to neutral conductor) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |