PACT RCP-4000A-1A-D140-3M-UV 1058044 PHOENIX CONTACT Set consisting of one 1 A measuring transducer and one ..
PACT RCP-4000A-1A-D140-3M-UV
1058044
PHOENIX CONTACT
1 Pcs.
Automation > Current transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This PACT RCP-4000A-1A-D140-3M-UV 1058044 Phoenix Contact set consisting of one 1 A measuring transducer and one measuring coil provides comprehensive current measurement solutions. These assemblies convert alternating currents into proportional secondary signals for safe panel metering and automation feedback. Relevant technical data is provided below.
- Orderkey: 1058044
- Packing unit: 1
- Catalog page: Page 224 (C-5-2019)
- GTIN: 4055626702261
- Custom tariff number: 85437090
- Width: 22.5 mm
- Height: 85 mm
- Depth: 70.4 mm
- Ambient temperature (operation): -30 °C ... 80 °C (Measuring coil)
- Ambient temperature (storage/transport): -40 °C ... 80 °C (Measuring coil)
- Maximum altitude: < 2000 m
- Permissible humidity (operation): 5 % ... 95 % (non-condensing) Measuring coil degree of protection: IP67 (not assessed by UL)
- Measuring transducer degree of protection: IP20
- Nominal supply voltage: 24 V DC -20 % ... +25 %
- Nominal supply voltage range: 19.2 V DC ... 30 V DC
Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
More info
▲Key Commercial Data
| Orderkey | 1058044 |
|---|---|
| Packing unit | 1 |
| Catalog page | Page 224 (C-5-2019) |
| GTIN | 4055626702261 |
| Custom tariff number | 85437090 |
Ambient conditions
| Ambient temperature (operation) | -30 °C ... 80 °C (Measuring coil) |
|---|---|
| -20 °C ... 70 °C (Measuring transducer) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C (Measuring coil) |
| -25 °C ... 85 °C (Measuring transducer) | |
| Maximum altitude | < 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Measuring coil degree of protection | IP67 (not assessed by UL) |
| Measuring transducer degree of protection | IP20 |
Measuring transducer supply
| Nominal supply voltage | 24 V DC -20 % ... +25 % |
|---|---|
| Nominal supply voltage range | 19.2 V DC ... 30 V DC |
| Max. current consumption | 190 mA |
| Power consumption | 4 W |
Measuring coil input data
| Frequency measuring range | 40 Hz ... 20000 Hz |
|---|---|
| Position error | < 1 % |
| Linearity error | 0.1 % |
Measuring transducer input data
| Measuring ranges (current) | 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A |
|---|---|
| Configurable/programmable | Via DIP switches |
| Phase angle | < 1 ° |
| Rated power | 1.5 VA |
| Max. distances for copper cables at PN max | 32 m (0.75 mm² (AWG 20)) |
| 64 m (1.5 mm² (AWG 16)) | |
| 107 m (2.5 mm² (AWG 14)) |
Measuring transducer signal input
| Input signal (at 50 Hz) | 100 mV (1000 A) |
|---|---|
| Input impedance | 27 kΩ (smallest measuring range) |
Measuring coil signal output
| Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
|---|---|
| Output voltage (in no-load operation) | VOUT= M * dI/dt |
| Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A)) |
General data, measuring coil
| Length of measuring coil | 450 mm |
|---|---|
| Diameter of measuring coil | 8.3 mm ±0.2 mm |
| Length of signal cable | 3000 mm |
| Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) |
| 1x 0.22 mm (Shielding (tinned)) | |
| Coil material | Elastollan |
| Housing material | PC |
| Insulation | double insulation |
| Rated insulation voltage | 1000 V AC (rms CAT III) |
| 600 V AC (rms CAT IV) | |
| Test voltage | 10.45 kV (DC / 1 min.) |
| Basic accuracy |
General data for measuring transducer
| Linearity error | < 0.5 % (From the range end value) |
|---|---|
| Maximum transmission error | ≤ 0.5 % (From the range end value) |
| Frequency range | 45 Hz ... 65 Hz |
| Max. detectable harmonics | < 2 kHz |
| Current consumption | < 190 mA (at 19.2 V) |
| Housing material | Polyamide |
| Test voltage | 1.5 kV AC (Supply/input and output: 50 Hz, 1 min) |
| Operating voltage display | Green LED |
| UL, USA/Canada | UL 508 Listed |
General data
| Standards/regulations | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| Insulation | double insulation |
| Temperature coefficients | 0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature) |
| 0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature) | |
| Typical measuring error | < 1 % |
Connection data
| Connection name | Measuring transducer side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
Standards and Regulations
| Standards/regulations | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| Insulation | double insulation |
| Pollution degree | 2 |
| Overvoltage category | III (1000 V, to neutral conductor) |
| IV (600 V, to neutral conductor) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 4.0 | 27210900 |
|---|---|
| eCl@ss 4.1 | 27210900 |
| eCl@ss 5.0 | 27210900 |
| eCl@ss 5.1 | 27210900 |
| eCl@ss 6.0 | 27210900 |
| eCl@ss 7.0 | 27210902 |
| eCl@ss 9.0 | 27210902 |