View larger
IB IL AO 2/UI-PAC 2700775 PHOENIX CONTACT Inline terminal
IB IL AO 2/UI-PAC
2700775
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for modular control installations, the Phoenix Contact IB IL AO 2/UI-PAC Inline terminal provides analog output channels for driving actuators and regulating variables like speed or position. Analog output modules translate digital control directives into continuous electrical signals used across automated production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): No
- Input signal, configurable (EF003209): No
- Output, current (EF003212): Yes
- Output, voltage (EF003213): Yes
- Output signal configurable (EF003214): Yes
- Resolution of the analogue outputs (EF003577): 12 Bit
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 2
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): Yes
More info
▲Key Commercial Data
| Orderkey | 2700775 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 167 (C-6-2017) |
| GTIN | 4046356639965 |
| Weight per Piece (excluding packing) | 66.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 12.2 mm |
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 66 g |
| Note on weight specifications | with connector |
| Diagnostics messages | Failure of the internal I/O supply I/O error message sent to the bus coupler |
| I/O supply failure Message in the diagnostic code (in the IB IL format) | |
| Short circuit/overload of the outputs Message in the diagnostic code (in the IB IL format) | |
| Configuration invalid Message in the diagnostic code (in the IB IL format) |
Interfaces
| Designation | Inline local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps |
| Transmission physics | Copper |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 55 mA |
| max. 65 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 24 mA (No-load) |
| max. 30 mA (No-load) | |
| typ. 38 mA (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ)) | |
| max. 45 mA (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ)) | |
| typ. 65 mA (Nominal current load (IOUT1/2= 20 mA, RL= 0 Ω)) | |
| max. 75 mA (Nominal current load (IOUT1/2= 20 mA, RL= 0 Ω)) | |
| Power consumption | typ. 1.32 W (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ)) |
Analog outputs
| Number of outputs | 2 |
|---|---|
| Connection technology | 2-wire |
| Note regarding the connection technology | shielded |
| Output name | Analog outputs |
| D/A conversion time | typ. 10 µs |
| D/A resolution | 12 bit |
| Type of protection | Short-circuit and overload protection |
| Transient protection | |
| Protective circuit/component | Electronic |
| Suppressor diode | |
| Data formats | IB IL, S7-compatible |
| Representation of output values | 12 bits (11 bits + sign bit) |
| Process data update | bus-synchronous |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| -20 mA ... 20 mA | |
| Load/output load current output | ≤ 450 Ω |
| Voltage output signal | 0 V ... 10 V |
| -10 V ... 10 V | |
| Load/output load voltage output | > 1 kΩ |
| Precision | typ. 0.1 % (of output range final value) |
| Permissible cable length | max. 250 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812) |
Electrical isolation
| Test section | 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min. |
|---|---|
| 7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min. | |
| 24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |