PHOENIX CONTACT IB IL 24 DO16-2MBD-PAC IB IL 24 DO16-2MBD-PAC 2862013 PHOENIX CONTACT Inline terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL 24 DO16-2MBD-PAC 2862013 PHOENIX CONTACT Inline terminal

IB IL 24 DO16-2MBD-PAC

2862013

PHOENIX CONTACT

1 Pcs.

Inline terminal Inline, Digital output module, Digital outputs:16, 24 VDC, 500 mA, connection technology:3 conductors, transmission speed on the local bus:2 MBit/s, protection index: IP20, including Inline connectors and marking fields

Automation > Fieldbus, decentr. periphery - digital I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact Inline terminal (part number IB IL 24 DO16-2MBD-PAC) functions as a specialized bus-communicating output module designed to switch standard 24 V loads within modular automation islands. Devices of this type mount inside control cabinets to interface PLC systems cleanly with field-level actuators. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Number of digital inputs (EF001992): 0
  • Number of digital outputs (EF001993): 16
  • Digital inputs configurable (EF008516): No
  • Digital outputs configurable (EF008520): No
  • Type of voltage (input voltage) (EF003033): DC
  • Permitted voltage at output (EF007553): 24 V
  • Short-circuit protection, outputs available (EF003203): Yes
  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0
  • Number of HW-interfaces parallel (EF003026): 0

More info

▲

Key Commercial Data

Orderkey2862013
Packing unit1 pc
Catalog pagePage 275 (AX-2009)
GTIN4017918974657
Weight per Piece (excluding packing)130.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width48.8 mm
Height140.5 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight130 g
Note on weight specificationswith connectors
Operating modeProcess data mode with one word
Diagnostics messagesShort-circuit / overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed2 Mbps

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptionmax. 105 mA
Power consumptionmax. 0.79 W
DesignationSegment circuit supply (US)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 8 A

Digital outputs

Output nameDigital outputs
Connection methodSpring-cage connection
Connection technology3-wire
Number of outputs16
Type of protectionOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US- 1 V)
Nominal output voltage24 V DC (voltage difference at Inom≤ 1 V)
Maximum output current per channel500 mA
Maximum output current per module8 A
Nominal load, inductive12 W
Nominal load, lamp12 W
Nominal load, ohmic12 W

Electrical isolation

Test section5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values