PHOENIX CONTACT IB IL 24 LPSDO 8 V2-PAC IB IL 24 LPSDO 8 V2-PAC 2700606 PHOENIX CONTACT Safety module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL 24 LPSDO 8 V2-PAC 2700606 PHOENIX CONTACT Safety module

IB IL 24 LPSDO 8 V2-PAC

2700606

PHOENIX CONTACT

1 Pcs.

Safety module Safety-oriented digital output module, IP20 degree of protection, for the SafetyBridge system. The module has 4 secure digital outputs with two-channel occupancy or 8 secure digital outputs with single-channel occupancy

Automation > Fieldbus, decentr. periphery - digital I/O module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Applied within modular safety architectures, the Phoenix Contact IB IL 24 LPSDO 8 V2-PAC Safety module evaluates and distributes protective signals across machine sub-assemblies. Modular safety I/O units safeguard personnel by ensuring dependable disconnection of power when emergency conditions occur.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Width: 48.8 mm
  • Height: 119.8 mm
  • Depth: 71.5 mm
  • Note on dimensions: Housing dimensions
  • Note on application Note on application: Only for industrial use
  • Inline local bus No. of channels: 2
  • Connection method: Inline data jumper
  • Transmission speed: 500 kbps / 2 Mbps (can be switched)
  • SafetyBridge properties Connection to I/O modules: max. 5 (safe digital I/O modules)
  • Logic memory: 24 kByte
  • Module ID code (dec.): 171
  • ID code (hex): AB
  • Length code (hex): 18
  • Length code (dec): 24
  • Process data channel: 48 Byte
  • Input address area: 48 Byte ((Operating mode: SafetyBridge 24 words))

More info

▲
Technical data

Dimensions
Dimensional drawing
Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Inline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps (can be switched)

System properties
SafetyBridge properties
Connection to I/O modulesmax. 5 (safe digital I/O modules)
Logic memory24 kByte
Module
ID code (dec.)171
ID code (hex)AB
Length code (hex)18
Length code (dec)24
Process data channel48 Byte
Input address area48 Byte ((Operating mode: SafetyBridge 24 words))
Output address area48 Byte ((Operating mode: SafetyBridge 24 words))
Register length48 Byte
Required parameter data1 Byte ((Operating mode: SafetyBridge 24 words))
Required configuration data5 Byte ((Operating mode: SafetyBridge 24 words))

Output data
Digital:
Output nameDigital outputs
Connection methodSpring-cage connection
Connection technology2-, 3-, 4-conductor
Number of outputs4 (for 2-channel assignment)
8 (for 1-channel assignment)
8
Protective circuitOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US- 1 V)
Output currentmax. 6 A (Total current of all outputs, -25 °C ... 50 °C)
max. 4 A (Total current of all outputs, >50 °C ... 55 °C)
Maximum output current per group3 A
Maximum output current per channel2 A
Nominal output voltage24 V DC
Nominal load, inductivesee safety data
Nominal load, lampsee safety data
Nominal load, ohmicsee safety data
Behavior with inductive overloadOutput can be destroyed

Product properties
Product typeI/O component
Product familyInline
ApplicationFunctional safety
SafetyBridge technology
Typemodular
Diagnostics messagesShort-circuit or overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor
Data management status
Article revision07

Electrical properties
Maximum power dissipation for nominal condition144 W
Transmission mediumCopper
Potentials: Communications power (UL)
Supply voltage7.5 V DC (see safety data)
Current drawmax. 230 mA (see safety data)
Potentials: Main circuit supply (UM)
Supply voltage24 V DC (see safety data)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 6.03 A
typ. 30 mA (all outputs set including actuator current)
Potentials: Segment circuit supply (US)
Supply voltage24 V (see safety data)
Supply: Module electronics
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameInline connector
pluggableyes
Conductor connection
Connection methodSpring-cage connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Inline connector
Connection methodSpring-cage connection
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 55 °C
Degree of protectionIP20
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting
Mounting typeDIN rail mounting