View larger
IB IL 24 LPSDO 8 V2-PAC 2700606 PHOENIX CONTACT Safety module
IB IL 24 LPSDO 8 V2-PAC
2700606
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Applied within modular safety architectures, the Phoenix Contact IB IL 24 LPSDO 8 V2-PAC Safety module evaluates and distributes protective signals across machine sub-assemblies. Modular safety I/O units safeguard personnel by ensuring dependable disconnection of power when emergency conditions occur.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width: 48.8 mm
- Height: 119.8 mm
- Depth: 71.5 mm
- Note on dimensions: Housing dimensions
- Note on application Note on application: Only for industrial use
- Inline local bus No. of channels: 2
- Connection method: Inline data jumper
- Transmission speed: 500 kbps / 2 Mbps (can be switched)
- SafetyBridge properties Connection to I/O modules: max. 5 (safe digital I/O modules)
- Logic memory: 24 kByte
- Module ID code (dec.): 171
- ID code (hex): AB
- Length code (hex): 18
- Length code (dec): 24
- Process data channel: 48 Byte
- Input address area: 48 Byte ((Operating mode: SafetyBridge 24 words))
More info
▲| Dimensional drawing | |
| Width | 48.8 mm |
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
| Note on application | |
| Note on application | Only for industrial use |
| Inline local bus | |
| No. of channels | 2 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps / 2 Mbps (can be switched) |
| SafetyBridge properties | |
| Connection to I/O modules | max. 5 (safe digital I/O modules) |
| Logic memory | 24 kByte |
| Module | |
| ID code (dec.) | 171 |
| ID code (hex) | AB |
| Length code (hex) | 18 |
| Length code (dec) | 24 |
| Process data channel | 48 Byte |
| Input address area | 48 Byte ((Operating mode: SafetyBridge 24 words)) |
| Output address area | 48 Byte ((Operating mode: SafetyBridge 24 words)) |
| Register length | 48 Byte |
| Required parameter data | 1 Byte ((Operating mode: SafetyBridge 24 words)) |
| Required configuration data | 5 Byte ((Operating mode: SafetyBridge 24 words)) |
| Digital: | |
| Output name | Digital outputs |
| Connection method | Spring-cage connection |
| Connection technology | 2-, 3-, 4-conductor |
| Number of outputs | 4 (for 2-channel assignment) |
| 8 (for 1-channel assignment) | |
| 8 | |
| Protective circuit | Overload protection, short-circuit protection of outputs |
| Output voltage | 24 V DC (US- 1 V) |
| Output current | max. 6 A (Total current of all outputs, -25 °C ... 50 °C) |
| max. 4 A (Total current of all outputs, >50 °C ... 55 °C) | |
| Maximum output current per group | 3 A |
| Maximum output current per channel | 2 A |
| Nominal output voltage | 24 V DC |
| Nominal load, inductive | see safety data |
| Nominal load, lamp | see safety data |
| Nominal load, ohmic | see safety data |
| Behavior with inductive overload | Output can be destroyed |
| Product type | I/O component |
| Product family | Inline |
| Application | Functional safety |
| SafetyBridge technology | |
| Type | modular |
| Diagnostics messages | Short-circuit or overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor |
| Data management status | |
| Article revision | 07 |
| Maximum power dissipation for nominal condition | 144 W |
| Transmission medium | Copper |
| Potentials: Communications power (UL) | |
| Supply voltage | 7.5 V DC (see safety data) |
| Current draw | max. 230 mA (see safety data) |
| Potentials: Main circuit supply (UM) | |
| Supply voltage | 24 V DC (see safety data) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 6.03 A |
| typ. 30 mA (all outputs set including actuator current) | |
| Potentials: Segment circuit supply (US) | |
| Supply voltage | 24 V (see safety data) |
| Supply: Module electronics | |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Connection technology | |
| Connection name | Inline connector |
| pluggable | yes |
| Conductor connection | |
| Connection method | Spring-cage connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Inline connector | |
| Connection method | Spring-cage connection |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Ambient conditions | |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Degree of protection | IP20 |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |