PHOENIX CONTACT OPT-5DC/230AC/ 1 OPT- 5DC/230AC/ 1 2982139 PHOENIX CONTACT Miniature solid-state relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OPT- 5DC/230AC/ 1 2982139 PHOENIX CONTACT Miniature solid-state relay

OPT-5DC/230AC/ 1

2982139

PHOENIX CONTACT

10 Pcs.

Miniature solid-state relay Plug-in miniature solid-state relay, power solid-state relay, 1 closing contact, input: 5 V DC, output: 24-253 V AC/ 0.75 A

Automation > Optocoupler
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

OPT- 5DC/230AC/ 1 2982139 PHOENIX CONTACT Miniature solid-state relay components act as compact switching interfaces that bridge low-voltage control electronics with AC-powered loads. They protect delicate automation hardware by providing galvanic isolation and dependable signal transfer in space-constrained cabinets.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Single solid-state relay
  • Operating mode: 100% operating factor
  • Data management status Date of last data management: 07.10.2024
  • Article revision: 00
  • Pollution degree: 2
  • Standards/regulations Rated insulation voltage: 260 V AC
  • Rated surge voltage: 4 kV (Basic insulation)
  • Nominal input voltage U N: 5 V DC
  • Input voltage range in reference to U N: 0.8 ... 1.2
  • Input voltage range: 4 V DC ... 6 V DC
  • Switching threshold "0" signal in reference to U N: 0.2
  • Switching threshold "1" signal in reference to U N: 0.6
  • Typical input current at U N: 7 mA
  • Typical response time: 10 ms
  • Typical turn-off time: 10 ms
  • Transmission frequency: 10 Hz

More info

▲
Technical data

Product properties
Product typeSingle solid-state relay
Operating mode100% operating factor
Data management status
Date of last data management07.10.2024
Article revision00
Insulation characteristics: Standards/regulations
Overvoltage categoryIII
Pollution degree2

Electrical properties
Standards/regulations
Rated insulation voltage260 V AC
Rated surge voltage4 kV (Basic insulation)

Input data
Nominal input voltage UN5 V DC
Input voltage range in reference to UN0.8 ... 1.2
Input voltage range4 V DC ... 6 V DC
Switching threshold "0" signal in reference to UN0.2
Switching threshold "1" signal in reference to UN0.6
Typical input current at UN7 mA
Typical response time10 ms
Typical turn-off time10 ms
Transmission frequency10 Hz

Output data
Contact switching type1 N/O contact
Design of digital outputelectronic
Output voltage range24 V AC ... 253 V AC
Limiting continuous current0.75 A (see derating curve)
Maximum inrush current30 A (10 ms)
Min. load current10 mA
Leakage current< 1 mA (in off state)
Phase angle cos phi min0.5
Max. load value4.5 A2s
Voltage drop at max. limiting continuous current< 1 V
Output circuit2-conductor floating, zero voltage switch
Protective circuitRCV circuit; RCV circuit

Dimensions
Dimensional drawing
Width5 mm
Height28 mm
Depth15 mm

Material specifications
Colorblack (RAL 9005)

Environmental and real-life conditions
Ambient conditions
Degree of protectionRT III
Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C

Approvals
Corrosive gas test
IdentificationISA-S71.04. G3 Harsh Group
EN 60068-2-60

Standards and regulations
Standards/regulations
Standards/regulationsIEC 60664
EN 50178

Mounting
Assembly notein rows with zero spacing
Mounting positionany

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.