A Phoenix Contact network cable NBC-MSX/ 2,0-94S/MSX SCO RAIL is designed specifically for railway and heavy-duty industrial applications requiring robust, high-speed Ethernet communication. Screened construction protects data signals against severe electromagnetic disturbances common in transit and traction environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 8
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Male (plug)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 2 m
- Halogen free (EF000025): Yes
- Colour cable sheath (EF008249): Black
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Vulcanize (EF004115): No
- Rated current In (EF008250): 0.5 A
- Rated voltage (EF000228): 48 V
- Degree of protection (IP) (EF005474): IP65
More info
▲Key Commercial Data
| Orderkey | 1415595 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 408 (C-2-2017) |
| GTIN | 4055626047645 |
| Weight per Piece (excluding packing) | 151.900 g |
| Custom tariff number | 85444210 |
| Country of origin | PL (Poland) |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 90 °C (M12 connector) |
General data
| Rated current at 40°C | 0.5 A |
|---|---|
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 8 |
| Signal type/category | Ethernet CAT6A, 10 Gbps |
| Standards/regulations | M12 connector IEC 61076-2-109 |
| Shock, vibration EN 50155 |
Characteristics head 1
| Head type | Plug straight M12 SPEEDCON / IP67 |
|---|---|
| No. of positions (pin connector pattern) | 8 |
| Coding | X (Data) |
| Color | black |
| Material (component) | CuZn (Contact) |
| Ni/Au (Contact surface) | |
| TPU (Contact carriers) | |
| PA 6.6 (Grip) | |
| Zinc die-cast, nickel-plated (Screw connection) | |
| Standards/regulations material | PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Insulation resistance | ≥ 100 MΩ |
| Insertion/withdrawal cycles | ≥ 100 |
| Torque | 0.4 Nm |
| Ambient temperature (operation) | -25 °C ... 90 °C |
Characteristics head 2
| Head type | Plug straight M12 SPEEDCON / IP67 |
|---|---|
| No. of positions (pin connector pattern) | 8 |
| Coding | X (Data) |
| Color | black |
| black | |
| Material (component) | CuZn (Contact) |
| Ni/Au (Contact surface) | |
| TPU (Contact carriers) | |
| PA 6.6 (Grip) | |
| Zinc die-cast, nickel-plated (Screw connection) | |
| Standards/regulations material | PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Insulation resistance | ≥ 100 MΩ |
| Insertion/withdrawal cycles | ≥ 100 |
| Torque | 0.4 Nm |
| Ambient temperature (operation) | -25 °C ... 90 °C |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-109 |
| Standard designation | Shock, vibration |
| Standards/regulations | EN 50155 |
Cable
| Cable type | Ethernet for rail applications |
|---|---|
| Cable type (abbreviation) | 94S |
| Signal type/category | Ethernet CAT7, 10 Gbps |
| Cable structure | 4x2xAWG26/7; S/FTP |
| Conductor cross section | 4x 2x 0.14 mm² |
| AWG signal line | 26 |
| Conductor structure signal line | 7x 0.16 mm |
| Core diameter including insulation | 1.05 mm ±0.1 mm |
| Wire colors | White-blue, white-orange, white-green, white-brown |
| Twisted pairs | 2 cores to the pair |
| Type of pair shielding | Aluminum-lined polyester foil |
| Overall twist | 4 pairs, twisted |
| Shielding | Tinned copper braided shield |
| External sheath, color | black |
| External cable diameter D | 6.6 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 6 x D |
| Tensile strength GRP | ≤ 60 N (temporary) |
| ≤ 15 N (Permanent) | |
| Cable weight | 59 kg/km |
| Copper weight | 28 kg/km |
| Outer sheath, material | PE-X |
| Material conductor insulation | Cell PE |
| Conductor material | Tin-plated Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km |
| Conductor resistance | ≤ 145 Ω/km |
| Working capacitance | 44 nF (per kilometer) |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Near end crosstalk attenuation (NEXT) | 100 dB (with 1 MHz) |
| 99 dB (at 10 MHz) | |
| 95 dB (at 100 MHz) | |
| 92 dB (at 200 MHz) | |
| 90 dB (at 250 MHz) | |
| 83 dB (at 500 MHz) | |
| 81 dB (at 600 MHz) | |
| 80 dB (at 700 MHz) | |
| 77 dB (at 800 MHz) | |
| 75 dB (at 900 MHz) | |
| 74 dB (at 1000 MHz) | |
| 72 dB (at 1100 MHz) | |
| 70 dB (at 1200 MHz) | |
| Power-summated near end crosstalk attenuation (PSNEXT) | 97 dB (with 1 MHz) |
| 96 dB (at 10 MHz) | |
| 92 dB (at 100 MHz) | |
| 89 dB (at 200 MHz) | |
| 87 dB (at 250 MHz) | |
| 80 dB (at 500 MHz) | |
| 78 dB (at 600 MHz) | |
| 77 dB (at 700 MHz) | |
| 74 dB (at 800 MHz) | |
| 72 dB (at 900 MHz) | |
| 71 dB (at 1000 MHz) | |
| 69 dB (at 1100 MHz) | |
| 67 dB (at 1200 MHz) | |
| Attenuation | 0.25 dB (with 1 MHz) |
| 0.76 dB (at 10 MHz) | |
| 2.49 dB (at 100 MHz) | |
| 3.69 dB (at 200 MHz) | |
| 4.18 dB (at 250 MHz) | |
| 5.6 dB (at 500 MHz) | |
| 6.74 dB (at 600 MHz) | |
| 7.32 dB (at 700 MHz) | |
| 7.89 dB (at 800 MHz) | |
| 8.5 dB (at 900 MHz) | |
| 9.11 dB (at 1000 MHz) | |
| 9.5 dB (at 1100 MHz) | |
| 9.9 dB (at 1200 MHz) | |
| Return loss (RL) | 24 dB (with 1 MHz) |
| 33.9 dB (at 10 MHz) | |
| 38.3 dB (at 100 MHz) | |
| 35.3 dB (at 200 MHz) | |
| 32.9 dB (at 250 MHz) | |
| 29.7 dB (at 500 MHz) | |
| 30.6 dB (at 600 MHz) | |
| 31 dB (at 700 MHz) | |
| 26.7 dB (at 800 MHz) | |
| 28.6 dB (at 900 MHz) | |
| 27.5 dB (at 1000 MHz) | |
| 26.9 dB (at 1100 MHz) | |
| 26.3 dB (at 1200 MHz) | |
| Crosstalk attenuation (ACR) | 100 dB (with 1 MHz) |
| 99 dB (at 10 MHz) | |
| 93 dB (at 100 MHz) | |
| 88 dB (at 200 MHz) | |
| 86 dB (at 250 MHz) | |
| 78 dB (at 500 MHz) | |
| 74 dB (at 600 MHz) | |
| 72 dB (at 700 MHz) | |
| 69 dB (at 800 MHz) | |
| 67 dB (at 900 MHz) | |
| 65 dB (at 1000 MHz) | |
| 63 dB (at 1100 MHz) | |
| 61 dB (at 1200 MHz) | |
| Power-summated crosstalk attenuation (PS-ACR) | 97 dB (with 1 MHz) |
| 96 dB (at 10 MHz) | |
| 90 dB (at 100 MHz) | |
| 85 dB (at 200 MHz) | |
| 83 dB (at 250 MHz) | |
| 75 dB (at 500 MHz) | |
| 71 dB (at 600 MHz) | |
| 69 dB (at 700 MHz) | |
| 66 dB (at 800 MHz) | |
| 64 dB (at 900 MHz) | |
| 62 dB (at 1000 MHz) | |
| 60 dB (at 1100 MHz) | |
| 58 dB (at 1200 MHz) | |
| Signal speed | 0.78 c |
| Signal runtime | 4.4 ns/m |
| Shield attenuation | 60 dB (up to 1000 MHz) |
| Interference suppression | 90 dB (up to 1000 MHz) |
| Coupling resistance | 5.00 mΩ/m (at 10 MHz) |
| Nominal voltage, cable | 125 V AC (Uo) |
| Test voltage Core/Core | 1000 V AC (50 Hz, 1 min.) |
| Test voltage Core/Shield | 1000 V AC (50 Hz, 1 min.) |
| Fire protection in rail vehicles | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
| DIN 5510-2 (Fire protection level 1, 2, 3, 4) | |
| EN 45545-2 | |
| EN 50306-4 | |
| NF F16-101 (Classification C/F1) | |
| NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B) | |
| NFPA 130 | |
| PN-K-02511 (Class A) | |
| UIC 564-2 (Class A) | |
| Flame resistance | according to EN 60332-1-2 |
| EN 60332-3-25 | |
| according to ISO 14572 5.21 (UN ECE-R 118.01) | |
| Halogen-free | According to EN 50267-2-1 |
| according to EN 60684-2 | |
| Resistance to oil | according to EN 60684-2, 72 h at 100 °C, IRM 902 |
| Other resistance | Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903 |
| Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-6 | |
| Concentration of fumes | EN 61034-2 |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |