View larger
NBC-R4AC1/0,3-94G/R4AC1-BU 1413158 PHOENIX CONTACT Patch cable
NBC-R4AC1/0,3-94G/R4AC1-BU
1413158
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact NBC-R4AC1/0,3-94G/R4AC1-BU patch cable delivers high-speed data transmission for industrial Ethernet network configurations. Preassembled network patch leads are standard components used to link switches, routing equipment, and automation terminals within control enclosures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Data cable preassembled
- Sensor type: Ethernet
- Number of positions: 8
- Connection profile: RJ45
- Shielded: yes
- Status display: no
- Status display present: No
- Rated voltage (III/3): 72 V (DC)
- Nominal voltage U N: 48 V
- Nominal current I N: 0.5 A
- Transmission medium: Copper
- Transmission speed: 10 Gbps
- Mechanical data Insertion/withdrawal cycles: 200
- Insertion force per signal contact: 50.00 N
- Extraction force per signal contact: 30 N
- Contact material: CuZn
More info
▲| Product type | Data cable preassembled |
| Sensor type | Ethernet |
| Number of positions | 8 |
| Connection profile | RJ45 |
| Shielded | yes |
| Status display | no |
| Status display present | No |
| Rated voltage (III/3) | 72 V (DC) |
| Nominal voltage UN | 48 V |
| Nominal current IN | 0.5 A |
| Transmission medium | Copper |
| Transmission speed | 10 Gbps |
| Mechanical data | |
| Insertion/withdrawal cycles | 200 |
| Insertion force per signal contact | 50.00 N |
| Extraction force per signal contact | 30 N |
| Contact material | CuSn |
| Contact surface material | Au |
| Contact carrier material | PC |
| Outer sheath, material | PUR |
| Dimensional drawing | |
| Width | 12.6 mm |
| Height | 6.6 mm |
| Length | 40.05 mm |
| Connection technology | |
| Connection method | Pierce connection |
| Conductor connection | |
| Connection method | Pierce connection |
| Connection 1 | |
| Type | Plug straight RJ45 |
| Shielded | yes |
| Insertion/withdrawal cycles | ≥ 750 |
| Degree of protection | IP20 |
| Connection 2 | |
| Type | Plug straight RJ45 |
| Shielded | yes |
| Insertion/withdrawal cycles | ≥ 750 |
| Degree of protection | IP20 |
| Cable length | 0.30 m |
| Cable type | Ethernet 10 Gbit |
| Cable structure | 2x2xAWG26/7, S/FTP |
| Outer sheath, material | PUR |
| External sheath, color | water blue RAL 5021 |
| Conductor structure signal line | 6.00 mm +0.2 mm -0.1 mm |
| AWG signal line | 26 |
| Material wire insulation | PE |
| Shielding | S/FTP |
| Test voltage, cable | 1000 V DC (1 minute) |
| Cable insulation resistance | 2000 MΩ*km (500 V) |
| Coupling resistance | 30.00 mΩ/m (30 MHz) |
| Smallest bending radius, fixed installation | 50 mm (under load) |
| Smallest bending radius, movable installation | 25 mm (without load) |
| Halogen-free | according to IEC 60754-1 |
| Flame resistance | IEC 60332-1 |
| Ambient conditions | |
| Degree of protection | IP20 |
| IP20 | |
| Ambient temperature (operation) | -25 °C ... 60 °C (RJ45 connector) |
| Flame resistance | IEC 60332-1 |