Engineered for high-speed industrial communication, the Phoenix Contact NBC-MSD/42,0-939/MSD SCO RAIL network cable supports PROFINET protocols across extensive factory networks. Shielded construction protects critical data streams from electromagnetic interference in heavy industrial settings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Type of electrical connection, field-sided (EF005525): M12
- Type of plug-in contact, field sided (EF006269): Male (plug)
- Positioning cable feed, field-sided (EF005928): Straight
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Male (plug)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 42 m
- Halogen free (EF000025): Yes
- Colour cable sheath (EF008249): Black
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Vulcanize (EF004115): No
- Rated current In (EF008250): 4 A
- Rated voltage (EF000228): 48 V
- Degree of protection (IP) (EF005474): IP65
More info
▲General data
| Note | The cable is 100% electrically tested for continuity. |
|---|---|
| Rated current at 40°C | 4 A |
| Rated voltage | 48 V AC |
| 60 V DC | |
| Number of positions | 4 |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Contact material | CuSn |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
Characteristics head 1
| Head type | Plug straight M12 SPEEDCON / IP65 |
|---|---|
| No. of positions (pin connector pattern) | 4 |
| Coding | D (Data) |
| Color | black |
| Material (component) | CuSn (Contact) |
| Ni/Au (Contact surface) | |
| PA (Contact carriers) | |
| TPU, hardly inflammable, self-extinguishing (Grip) | |
| Zinc die-cast, nickel-plated (Screw connection) | |
| Shielded | yes |
| Insulation resistance | ≥ 100 MΩ |
| Test voltage | 500 V DC ±15 V DC (for 60 s, insulation resistance according to DIN EN 60512-3-1) |
| 1.4 kV AC (for 60 s, dielectric strength according to DIN EN 60512-4-1) | |
| Insertion/withdrawal cycles | ≥ 100 (Quantity: 500 with Phoenix Contact mating connector) |
| Torque | 0.4 Nm |
| Ambient temperature (operation) | -40 °C ... 90 °C |
| Weight | 10 g ±5 g |
Characteristics head 2
| Head type | Plug straight M12 SPEEDCON / IP65 |
|---|---|
| No. of positions (pin connector pattern) | 4 |
| Coding | D (Data) |
| Color | black |
| Material (component) | CuSn (Contact) |
| Ni/Au (Contact surface) | |
| PA (Contact carriers) | |
| TPU, hardly inflammable, self-extinguishing (Grip) | |
| Zinc die-cast, nickel-plated (Screw connection) | |
| Shielded | yes |
| Insulation resistance | ≥ 100 MΩ |
| Test voltage | 500 V DC ±15 V DC (for 60 s, insulation resistance according to DIN EN 60512-3-1) |
| 1.4 kV AC (for 60 s, dielectric strength according to DIN EN 60512-4-1) | |
| Insertion/withdrawal cycles | ≥ 100 (Quantity: 500 with Phoenix Contact mating connector) |
| Torque | 0.4 Nm |
| Ambient temperature (operation) | -40 °C ... 90 °C |
| Weight | 10 g ±5 g |
Standards and Regulations
| Standards/specifications | M12 connector IEC 61076-2-101 |
|---|---|
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | PROFINET railway applications |
|---|---|
| Cable type (abbreviation) | 939 |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Cable structure | 1x4xAWG22/7; SF/TQ |
| Conductor cross section | 4x 0.34 mm² |
| AWG signal line | 22 |
| Conductor structure signal line | 7x 0.25 mm |
| Core diameter including insulation | 1.4 mm ±0.1 mm |
| Wire colors | white-blue, orange-yellow |
| Overall twist | Star quad |
| Shielding | Aluminum-lined polyester foil, tinned copper braided shield |
| External sheath, color | black |
| Outer sheath thickness | 1 mm |
| External cable diameter D | 6.6 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 6 x D |
| Tensile strength GRP | ≤ 60 N (temporary) |
| ≤ 15 N (Permanent) | |
| Cable weight | 71 kg/km |
| Outer sheath, material | PE-X |
| Material conductor insulation | Cell PE |
| Conductor material | Tin-plated Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km |
| Conductor resistance | ≤ 54.4 Ω/km |
| Cable capacity | 44 nF/km (core-core) |
| Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
| Near end crosstalk attenuation (NEXT) | 76 dB (with 1 MHz) |
| 71 dB (at 4 МHz) | |
| 64 dB (at 10 MHz) | |
| 60 dB (at 16 MHz) | |
| 56 dB (at 31.25 МHz) | |
| 52 dB (at 62.5 МHz) | |
| 48 dB (at 100 MHz) | |
| 45 dB (at 155 MHz) | |
| 42 dB (at 200 MHz) | |
| Power-summated near end crosstalk attenuation (PSNEXT) | 73 dB (with 1 MHz) |
| 68 dB (at 4 МHz) | |
| 61 dB (at 10 MHz) | |
| 57 dB (at 16 MHz) | |
| 53 dB (at 31.25 МHz) | |
| 49 dB (at 62.5 МHz) | |
| 45 dB (at 100 MHz) | |
| 42 dB (at 155 MHz) | |
| 39 dB (at 200 MHz) | |
| Attenuation | 1.5 dB (with 1 MHz) |
| 3.3 dB (at 4 МHz) | |
| 5.3 dB (at 10 MHz) | |
| 6.9 dB (at 16 MHz) | |
| 9.9 dB (at 31.25 МHz) | |
| 14.5 dB (at 62.5 МHz) | |
| 18.8 dB (at 100 MHz) | |
| 23.6 dB (at 155 MHz) | |
| 27.3 dB (at 200 MHz) | |
| Return loss (RL) | 25 dB (with 1 MHz) |
| 25 dB (at 4 МHz) | |
| 28 dB (at 10 MHz) | |
| 28 dB (at 16 MHz) | |
| 27 dB (at 31.25 МHz) | |
| 26 dB (at 62.5 МHz) | |
| 25 dB (at 100 MHz) | |
| 25 dB (at 155 MHz) | |
| 23 dB (at 200 MHz) | |
| Signal speed | 0.75 c |
| Signal runtime | 4.4 ns/m |
| Shield attenuation | 60 dB (up to 1000 MHz) |
| Coupling resistance | < 13.00 mΩ/m (f = 1 MHz) |
| < 8.00 mΩ/m (f = 10 MHz ... 100 MHz) | |
| Cable impedance | 100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz) |
| Nominal voltage, cable | 125 V |
| Test voltage Core/Core | 1000 V AC (50 Hz, 1 min.) |
| Test voltage Core/Shield | 1000 V AC (50 Hz, 1 min.) |
| Fire protection in rail vehicles | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
| DIN 5510-2 (Fire protection level 1, 2, 3, 4) | |
| EN 45545-2 (Risk level HL1 - HL3) | |
| EN 50306-4 | |
| NF F16-101 (Classification C/F1) | |
| NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B) | |
| NFPA 130 | |
| PN-K-02511 | |
| UIC 564-2 (Class A) | |
| Flame resistance | according to EN 60332-1-2 |
| according to EN 50266-2-5 | |
| according to ISO 14572 5.21 (UN ECE-R 118.01) | |
| Halogen-free | According to EN 50267-2-1 |
| according to EN 60684-2 | |
| Resistance to oil | according to EN 60684-2, 72 h at 100 °C, IRM 902 |
| Other resistance | Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903 |
| Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-6 | |
| Concentration of fumes | EN 61034-2 |
| Ambient temperature (operation) | -40 °C ... 85 °C (cable, fixed installation) |
| -25 °C ... 70 °C (cable, flexible installation) |