PHOENIX CONTACT NBC-MRD/ 1,5-93E/MRD SCO NBC-MRD/ 1,5-93E/MRD SCO 1421988 PHOENIX CONTACT Bus system cable NBC-MRD/ 1,5-93E/MRD SCO 1421988 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NBC-MRD/ 1,5-93E/MRD SCO 1421988 PHOENIX CONTACT Bus system cable NBC-MRD/ 1,5-93E/MRD SCO 1421988

NBC-MRD/ 1,5-93E/MRD SCO

1421988

PHOENIX CONTACT

50 Pcs.

Bus system cable - NBC-MRD/ 1,5-93E/MRD SCO - 1421988 Assembled Ethernet cable, CAT5e, shielded, 2-pair, 26 AWG stranded (7-wire), RAL 5021 (water blue), angled M12 SPEEDCON plug to angled M12 SPEEDCON plug, line, length: 1 m

Automation > Patch cord copper (twisted pair)
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

NBC-MRD/ 1,5-93E/MRD SCO 1421988 PHOENIX CONTACT Bus system cable NBC-MRD/ 1,5-93E/MRD SCO 1421988 acts as a robust data transmission medium for interconnecting automated production machinery. Such industrial network cables provide reliable shielding and signal propagation in high-noise environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Sensor type: Ethernet
  • Number of positions: 4
  • Signal type/category: Ethernet, 100 Mbps
  • Status display: no
  • Status display present: No
  • Nominal voltage U N: 48 V AC
  • Cable weight: 42 kg/km
  • UL AWM Style: 20963 (80°C/30 V)
  • Wiring standards/regulations: Electrical requirements EN 50288-2-2
  • Number of positions: 4
  • Shielded: yes
  • Cable type: Ethernet flexible CAT5, 2-pair [93E]
  • Conductor structure: 2x2xAWG26/7, SF/UTP
  • Signal runtime: 5.3 ns/m
  • Conductor structure signal line: 7x 0.16 mm

More info

▲
Technical data

Product properties
Product typeData cable preassembled
Sensor typeEthernet
Number of positions4

Interfaces
Signal type/categoryEthernet, 100 Mbps

Signaling
Status displayno
Status display presentNo

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)

Cable/line
Ethernet flexible CAT5, 2-pair [93E]
Dimensional drawing
Cable weight42 kg/km
UL AWM Style20963 (80°C/30 V)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Number of positions4
Shieldedyes
Cable typeEthernet flexible CAT5, 2-pair [93E]
Conductor structure2x2xAWG26/7, SF/UTP
Signal runtime5.3 ns/m
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section2x 2x 0.14 mm²
Wire diameter incl. insulation0.98 mm
External cable diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/orange-orange, white/green-green
Thickness, outer sheath1.20 mm
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 45 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 80 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
in acc. to UL VW1
in accordance with UN ECE-R 118.03
Resistance to oilin accordance with EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65/IP67

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.