PHOENIX CONTACT NBC-M12MRXC2/ 5,0-94F/R4AC NBC-M12MRXC2/ 5,0-94F/R4AC 1578922 PHOENIX CONTACT Network cable, Ethernet CAT6 sub to /sub CAT6 sub to /sub.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NBC-M12MRXC2/ 5,0-94F/R4AC 1578922 PHOENIX CONTACT Network cable, Ethernet CAT6 sub to /sub CAT6 sub to /sub..

NBC-M12MRXC2/ 5,0-94F/R4AC

1578922

PHOENIX CONTACT

25 Pcs.

Network cable, Ethernet CAT6toCAT6to(10 GBit/s), 8-pole, halogen-free PUR, water blue RAL 5021, M12 angled connector, encoding: X, a Straight RJ45 / IP20 connector, cable length: 5 m, C2 coding Network cable Network Cable, Ethernet CAT6A CAT6A (10 Gbit/s), 8-pin, Angled M12 Connector, Encoding: X, on Straight Connector RJ45 / IP20, Cable Length: 5 m, C2 Coding

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact network cable, part number NBC-M12MRXC2/ 5,0-94F/R4AC, is engineered for high-bandwidth Ethernet and data communication across automated industrial systems. CAT6A compliance guarantees high-speed performance for modern automation networks.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Data cable assembled
  • Sensor type: Ethernet
  • Number of poles: 8
  • Number of cable outlets: 1
  • Shielded: Yes
  • Coding: X
  • Signal Type/Category: Ethernet CAT6 A
  • Rated voltage U N: 48 V AC
  • Nominal current I N: 0.5 A
  • Transmission Characteristics (Category): CAT6 A
  • Port 1 Design: Connector angled M12
  • Number of poles: 8
  • Encoding type: X (Data)
  • Material: CuZn (Contact)
  • Port 2 Design: Plug straight RJ45 / IP20
  • Number of poles: 8

More info

▲

Product TypeData cable assembled
Sensor typeEthernet
Number of poles8
Number of cable outlets1
ShieldedYes
CodingX

Signal Type/CategoryEthernet CAT6A

Rated voltage UN48 V AC
60 V DC
Nominal current IN0.5 A
Transmission Characteristics (Category)CAT6A

Port 1
DesignConnector angled M12
Number of poles8
Encoding typeX (Data)
MaterialCuZn (Contact)
Ni/Au (contact surface)
PP (contact carrier)
TPU, flame retardant, self-extinguishing (handle body)
Die-cast zinc, nickel-plated (screw connection)
Port 2
DesignPlug straight RJ45 / IP20
Number of poles8
MaterialCuSn (Contact)
Ni/Au (contact surface)
PC (contact carrier)
PA (Housing)
Degree of protectionIP20

Cable length5 m
Ethernet 10 GBit [94F]
Dimensional drawing
ShieldedYes
UL AWM Style20963 (80 °C / 30 V)
Line weight42 kg/km
Line TypeEthernet 10 GBit
Abbreviation02YSC11Y
Cable type (characters)94F
Signal Type/CategoryEthernet CAT6A, 10 Gbit/s
Cable structure4x2xAWG26/7; S/FTP
Pipe outer diameter6.4 mm ±0.2 mm
Outer Jacket, MaterialPUR
Outer Jacket, Colourwater blue RAL 5021
Wall thickness outer jacket0.65 mm
Material Conductorbare copper wire
Conductor structure Signal cable7x 0.16 mm
AWG signal line26
Cable cross-section4x 2x 0.14 mm²
Material Core Insulationfoamed PE
Core diameter including insulation1.04 mm
Single wire, colourwhite/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Pair stranding2 wires to pair
Type of pair shieldingAluminum-laminated foil
Total stranding4 Couples to the Soul
ShieldingBraid of tinned copper wires
Optical screen covering70 %
Nominal voltage line≤ 100 V
Test voltage core/wire700 V (50 Hz, 1 min.)
Test voltage core/shield700 V (50 Hz, 1 min.)
Conduction Insulation Resistance≥ 500 MΩ*km
Impedance100 Ω ±5 Ω (at 100 MHz)
Loop resistance≤ 290.00 Ω/km
Line Capacity47 nF/km
Signal propagation time5.13 ns/m
Tensile strength≤ 100 N
Minimum bending radius, fixed4 x D
Minimum bending radius, flexibly laid8 x D
Damping3.1 dB (at 1 MHz)
5.7 dB (at 4 MHz)
8 dB (at 8 MHz)
8.9 dB (at 10 MHz)
11.2 dB (at 16 MHz)
12.6 dB (at 20 MHz)
14.1 dB (at 25 MHz)
15.8 dB (at 31.25 MHz)
22.5 dB (at 62.5 MHz)
28.7 dB (at 100 MHz)
41.4 dB (at 200 MHz)
46.6 dB (at 250 MHz)
51.4 dB (at 300 MHz)
60.1 dB (at 400 MHz)
67.9 dB (at 500 MHz)
Near Crosstalk Attenuation (NEXT)75.3 dB (at 1 MHz)
66.3 dB (at 4 MHz)
61.8 dB (at 8 MHz)
60.3 dB (at 10 MHz)
57.2 dB (at 16 MHz)
55.8 dB (at 20 MHz)
54.3 dB (at 25 MHz)
52.8 dB (at 31.25 MHz)
48.4 dB (at 62.5 MHz)
45.3 dB (at 100 MHz)
40.8 dB (at 200 MHz)
39.3 dB (at 250 MHz)
38.1 dB (at 300 MHz)
38.1 dB (at 400 MHz)
38.1 dB (at 500 MHz)
Power-summed near crosstalk attenuation (PSNEXT)72.3 dB (at 1 MHz)
63.3 dB (at 4 MHz)
58.8 dB (at 8 MHz)
57.3 dB (at 10 MHz)
54.2 dB (at 16 MHz)
52.8 dB (at 20 MHz)
51.3 dB (at 25 MHz)
49.9 dB (at 31.25 MHz)
45.4 dB (at 62.5 MHz)
42.3 dB (at 100 MHz)
37.8 dB (at 200 MHz)
36.3 dB (at 250 MHz)
35.1 dB (at 300 MHz)
33.3 dB (at 400 MHz)
31.8 dB (at 500 MHz)
Return Loss (RL)20 dB (at 1 MHz)
23 dB (at 4 MHz)
24.5 dB (at 8 MHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 MHz)
24.2 dB (at 25 MHz)
23.3 dB (at 31.25 MHz)
20.7 dB (at 62.5 MHz)
19 dB (at 100 MHz)
16.4 dB (at 200 MHz)
15.6 dB (at 250 MHz)
15.6 dB (at 300 MHz)
15.6 dB (at 400 MHz)
15.6 dB (at 500 MHz)
Shielding attenuation≥ 80 dB (at 30 ... 100 MHz)
Halogen-freeaccording to IEC 60754-1
Oil resistanceaccording to DIN EN 60811-2-1
Flame retardancyaccording to IEC 60332-1-2
Ambient temperature (operating)-20 °C ... 80 °C (cable, movable installation)
-40 °C ... 80 °C (cable, fixed installation)

Environmental conditions
Degree of protectionIP67/IP20

Product Datasheet