PHOENIX CONTACT NBC-M12FSBP/3,0-93E/R4AC NBC-M12FSBP/3,0-93E/R4AC 1412330 PHOENIX CONTACT Network cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NBC-M12FSBP/3,0-93E/R4AC 1412330 PHOENIX CONTACT Network cable

NBC-M12FSBP/3,0-93E/R4AC

1412330

PHOENIX CONTACT

50 Pcs.

Network cable Network cable, cable length: 3 m, number of poles: 4, CAT5, cable output: straight, Ethernet Network cable, cable length: 3 m, number of positions: 4, 100 Mbps, CAT5, cable outlet: straight, Ethernet

Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact NBC-M12FSBP/3,0-93E/R4AC is a network cable assembly engineered to connect industrial Ethernet nodes and controllers in automated manufacturing floors. Prefabricated industrial communication cables ensure stable high-speed data transmission between equipment racks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Mounting type: Rear wall/screw mounting
  • Product type: Circular connectors (device side)
  • Type: M12
  • Sensor type: Ethernet
  • Number of positions: 4
  • No. of cable outlets: 1
  • Shielded: yes
  • Cable outlet: straight
  • Data management status Article revision: 06
  • Insulation characteristics Degree of pollution: 3
  • Flammability rating according to UL 94: V2
  • Rated voltage (III/3): 72 V (DC)
  • Nominal voltage U N: 48 V
  • Nominal current I N: 2 A
  • Transmission medium: Copper
  • Transmission characteristics (category): CAT5 (IEC 11801:2002)

More info

▲
Technical data

Mounting
Mounting typeRear wall/screw mounting

Product properties
Product typeCircular connectors (device side)
TypeM12
Sensor typeEthernet
Number of positions4
No. of cable outlets1
Shieldedyes
Cable outletstraight
Data management status
Article revision06
Insulation characteristics
Degree of pollution3

Material specifications
Flammability rating according to UL 94V2

Electrical properties
Rated voltage (III/3)72 V (DC)
Nominal voltage UN48 V
Nominal current IN2 A
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Connector
Connection 1
TypeFlush-type female connector straight M12
Locking typeSPEEDCON
Coding typeD (Data)
Degree of protectionIP65/IP67
Connection 2
TypePlug straight RJ45
Degree of protectionIP20

Cable/line
Cable length3.00 m
Ethernet flexible CAT5, 2-pair [93E]
Dimensional drawing
Cable weight42 kg/km
UL AWM Style20963 (80°C/30 V)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Number of positions4
Shieldedyes
Cable typeEthernet flexible CAT5, 2-pair [93E]
Conductor structure2x2xAWG26/7, SF/UTP
Signal runtime5.3 ns/m
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section2x 2x 0.14 mm²
Wire diameter incl. insulation0.98 mm
External cable diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/orange-orange, white/green-green
Thickness, outer sheath1.20 mm
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 45 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 80 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
in acc. to UL VW1
in accordance with UN ECE-R 118.03
Resistance to oilin accordance with EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C