View larger
MUTTB 2,5 BU 3249014 PHOENIX CONTACT Mini-terminal block, nominal voltage: 500 V, nominal current: 22 A, con..
MUTTB 2,5 BU
3249014
PHOENIX CONTACT
50 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Utilized in confined spaces, the MUTTB 2,5 BU 3249014 Phoenix Contact mini-terminal block, nominal voltage: 500 V, nominal current: 22 A, con.. provides dependable conductor termination where standard DIN-rail components are too large. Mini terminals maintain high mechanical stability and electrical performance in compact control panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Miniterminal
- Number of poles: 2
- Number of connections: 4
- Number of rows: 2
- Potential: 2
- Insulation Properties Surge Category: Iii
- Degree of pollution: 3
- Maximum Dissipated Power with Nominal Condition: 0.77 W
- Number of connections per floor: 2
- Nominal Section: 2.5 mm²
- AWG Conductor Section: (Converted according to IEC)
- Screw thread: M3
- Peel Length: 7 mm ... 9 mm
- Male Gauge: A3
- Standard-compliant connection: IEC 60947-7-1
- Rigid conductor section: 0.2 mm² ... 4 mm²
More info
▲| Product Type | Miniterminal |
| Number of poles | 2 |
| Number of connections | 4 |
| Number of rows | 2 |
| Potential | 2 |
| Insulation Properties | |
| Surge Category | Iii |
| Degree of pollution | 3 |
| Maximum Dissipated Power with Nominal Condition | 0.77 W |
| Number of connections per floor | 2 |
| Nominal Section | 2.5 mm² |
| AWG Conductor Section | (Converted according to IEC) |
| Screw thread | M3 |
| Peel Length | 7 mm ... 9 mm |
| Male Gauge | A3 |
| Standard-compliant connection | IEC 60947-7-1 |
| Rigid conductor section | 0.2 mm² ... 4 mm² |
| AWG Conductor Section | 24 ... 12 (Converted according to IEC) |
| Flexible conductor section | 0.2 mm² ... 2.5 mm² |
| Flexible Wire Section [AWG] | 4 ... 14 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.25 mm² ... 2.5 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.25 mm² ... 2.5 mm² |
| 2 conductors with the same cross-section, rigid | 0.2 mm² ... 1.5 mm² |
| 2 conductors with the same rigid AWG cross-section | 24 ... 16 (Converted according to IEC) |
| 2 conductors with the same cross-section, flexible | 0.2 mm² ... 1.5 mm² |
| 2 conductors with the same flexible AWG cross-section | 24 ... 16 (Converted according to IEC) |
| 2 conductors of equal cross-section, flexible with toe cap, without plastic sleeve | 0.2 mm² ... 1.5 mm² |
| 2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve | 0.5 mm² ... 1.5 mm² |
| Nominal current | 22 A (with a conductor cross-section of 2.5 mm²) |
| Maximum Charging Current | 28 A (with 4 mm² cable cross-section) |
| Nominal voltage | 500 V |
| Nominal Section | 2.5 mm² |
| Width | 5.2 mm |
| Height | 63.5 mm |
| Depth | 50.8 mm |
| Depth at NS 15 | 51.6 mm |
| Depth at NS 35/7.5 | 52.3 mm |
| Depth at NS 35/15 | 59.8 mm |
| Colour | blue |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of cold insulating material | -60 °C |
| Relative Insulating Material Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Flammability of NFPA 130 Surfaces (ASTM E 162) | approved |
| NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) | approved |
| NFPA 130 Flue Gas Toxicity (SMP 800C) | approved |
| Impulse Voltage Test | |
| Result | Approved Test |
| Heating Verification | |
| Heating test requirement | Temperature rise ≤ 45 K |
| Result | Approved Test |
| Short-term permissible current 2.5 mm² | 0.3 kA |
| Result | Approved Test |
| Dielectric Strength with Operating Frequency | |
| Test Voltage Nominal Value | 1.89 kV |
| Result | Approved Test |
| Mechanical data | |
| Open sidewall | Yes |
| Mechanical resistance | |
| Result | Approved Test |
| Fixing on the bracket | |
| Rail/Fixing Surface | NS 35/7.5 |
| Result | Approved Test |
| Checking for damage to conductors and loosening | |
| Rotation speed | 10 r.p.m. |
| Rotations | 135 |
| Conductor Section/Weight | 0.2 mm2/0.2 kg |
| 2.5 mm2/0.7 kg | |
| 4 mm2/0.9 kg | |
| Result | Approved Test |
| Needle Flame Test | |
| Performance Time | 30 sec |
| Result | Approved Test |
| Broadband Oscillation/Noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Spectrum | Category 2 durability test, on the bogie |
| frequency | f1= 5 Hz to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test Directions | X, Y, and Z axes |
| Result | Approved Test |
| Crash | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Shock Type | Semi-sinusoid |
| Acceleration | 30g |
| Duration of the crash | 18 ms |
| Number of collisions per steering | 3 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Result | Approved Test |
| Environmental conditions | |
| Ambient Temperature (Service) | -60 °C ... 105 °C (for max. short-term operating temperature, see RTI Elec.) |
| Ambient Temperature (Storage/Transport) | -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C) |
| Ambient Temperature (Mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Drive) | -5 °C ... 70 °C |
| Permissible air humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 60947-7-1 |
| Type of mounting | NS 15 |
| NS 35/7.5 | |
| NS 35/15 |