View larger
PSR-SCP-24DC/MXF4/4X1/2X2/B 2903260 PHOENIX CONTACT Safety relays
PSR-SCP-24DC/MXF4/4X1/2X2/B
2903260
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Safety relays like the Phoenix Contact PSR-SCP-24DC/MXF4/4X1/2X2/B 2903260 are implemented in control cabinets to evaluate safety signals from machine sensors and safely interrupt power to actuators when necessary. They provide dependable switching for complex automation infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2903260
- Packing unit: 1 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 266 (C-6-2017)
- GTIN: 4046356729246
- Weight per Piece (excluding packing): 99.990 g
- Custom tariff number: 85371098
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 22.5 mm
- Height: 112.2 mm
- Depth: 114.5 mm
- Ambient temperature (operation): -20 °C ... 45 °C (see derating curve)
- Ambient temperature (storage/transport): -25 °C ... 85 °C
- Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
- Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
More info
▲Key Commercial Data
| Orderkey | 2903260 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 266 (C-6-2017) |
| GTIN | 4046356729246 |
| Weight per Piece (excluding packing) | 99.990 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 45 °C (see derating curve) |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | |
|---|---|
| Nominal input voltage UN | 24 V DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 125 mA (with actuated relays) |
| 55 mA (Two-channel 24 V/0 V + max. 200 mA control (message outputs 32/62) with non-actuated relays) | |
| Current consumption | typ. 5 mA (Imax/Ixinputs) |
| 20 mA (in electric torque) | |
| Voltage at input/start and feedback circuit | 24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V) |
| Typical response time | 175 ms (monitored/manual start) |
| 250 ms (automatic start) | |
| Typ. starting time with Us | 250 ms (when controlled via A1) |
| Typical release time | 25 ms (when controlled via S11/S12 and S21/S22) |
| 20 ms (when controlled via A1) | |
| Concurrence input 1/2 | ∞ |
| Recovery time | 1 s (Availability time after activation of sensor circuit: 100ms) |
| Operating voltage display | 1 x green LED |
| Status display | 5 green LEDs |
| Protective circuit | Surge protection Suppressor diode |
| Maximum switching frequency | 0.5 Hz |
| Max. permissible overall conductor resistance | 100 Ω |
| Filter time | max. 1.5 ms (Test pulse duration; for all equivalent inputs) |
| min. 7.5 ms (Test pulse rate; for all equivalent inputs) |
Output data
| Contact type | 4 enabling current paths |
|---|---|
| 2 semiconductor alarm outputs | |
| Contact material | AgCuNi, +0.2 -0.4 µm Au |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 10 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| max. 100 mA (Alarm output (24 V DC)) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(ITH2= I12+ I22+ I32+ I42) |
| Interrupting rating (ohmic load) max. | 1500 VA (250 V AC, τ = 0 ms) |
| 66 W (220 V DC, τ = 0 ms) | |
| 66 W (110 V DC, τ = 0 ms) | |
| 100 W (48 V DC, τ = 0 ms) | |
| 144 W (24 V DC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
| 43 W (48 V DC, τ = 40 ms) | |
| Switching capacity min. | 0.1 W |
| Mechanical service life | 10x 106cycles |
| Switching capacity (360/h cycles) | 5 A (0,1 Hz; DC13; 24 V) |
| Output fuse | 6 A gL/gG NEOZED (N/O contact) |
| 4 A gL/gG NEOZED (for low-demand applications) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 99.99 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing color | yellow |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Safety Integrity Level (SIL) | 3 |
| 3 | |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (5 A DC13; 3 A AC15; 8760 cycles/year) |
| Category | 4 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | 4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).) |
| Degree of pollution | 2 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |