Request QuoteProduct Overview
Phoenix Contact MTK-P/P RD knife disconnect terminal block incorporates a red housing and a straightforward lever mechanism to isolate specific circuit paths during routine servicing and diagnostic testing. Terminal blocks of this style are heavily deployed in industrial control environments to enhance safety and organization during maintenance. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 3074279
- Packing unit: 50 pc
- Minimum order quantity: 50 pc
- Note: Made to Order (non-returnable)
- GTIN: 4046356365925
- Weight per Piece (excluding packing): 9.770 g
- Custom tariff number: 85369010
- Country of origin: DE (Germany)
- Number of levels: 1
- Number of connections: 2
- Nominal cross section: 2.5 mm²
- Color: red
- Insulating material: PA
- Flammability rating according to UL 94: V0
- Rated surge voltage: 6 kV
- Degree of pollution: 3
More info
▲Key Commercial Data
| Orderkey | 3074279 |
|---|---|
| Packing unit | 50 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356365925 |
| Weight per Piece (excluding packing) | 9.770 g |
| Custom tariff number | 85369010 |
| Country of origin | DE (Germany) |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 2 |
| Nominal cross section | 2.5 mm² |
| Color | red |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 6 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Connection in acc. with standard | IEC 60947-7-1 |
| Nominal current IN | 16 A |
| Maximum load current | 16 A (with 4 mm² conductor cross section) |
| Nominal voltage UN | 400 V |
| Open side panel | Yes |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.5 mm² |
| 2 conductors with same cross section, solid min. | 0.2 mm² |
| 2 conductors with same cross section, solid max. | 1.5 mm² |
| 2 conductors with same cross section, stranded min. | 0.2 mm² |
| 2 conductors with same cross section, stranded max. | 1.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 0.25 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 1.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 1.5 mm² |
| Cross section with insertion bridge, solid max. | 4 mm² |
| Cross section with insertion bridge, stranded max. | 2.5 mm² |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Internal cylindrical gage | A3 |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
Standards and Regulations
| Connection in acc. with standard | CSA |
|---|---|
| IEC 60947-7-1 | |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |