View larger
FK-MC 0,5/ 7-ST-2,5 BD:1-7 1705552 PHOENIX CONTACT Plug-in part, rated current: 4 A, number of poles: 7, pit..
FK-MC 0,5/ 7-ST-2,5 BD:1-7
1705552
PHOENIX CONTACT
50 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact FK-MC 0,5/ 7-ST-2,5 BD:1-7 plug-in part delivers precise, space-saving connection performance for miniature electronic devices. Compact plug connectors are routinely implemented within instrumentation, sensor modules, and compact automation hardware to route control signals securely. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of poles (EF001391): 7
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 2.5 mm
- Modular spacing connections (EF006827): 2.5 mm
- Rated current In (EF008250): 4 A
- Rated voltage (EF000228): 160 V
- Rated surge voltage (EF002993): 2.5 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.14 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
More info
▲Plug component, nominal current: 4 A, number of positions: 7, pitch: 2.5 mm, connection method: Push-in spring connection, color: green, contact surface: Tin
Your advantages
Electrical parameters
| Rated current | 4 A |
|---|---|
| Rated insulation voltage (III/2) | 160 V |
| Rated surge voltage (III/2) | 2.5 kV |
Connection capacity
| Conductor cross section solid | 0.14 mm² ... 0.5 mm² |
|---|---|
| Conductor cross section flexible | 0.14 mm² ... 0.5 mm² |
| Conductor cross section AWG / kcmil | 26 ... 20 |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 0.5 mm² |
| Cylindrical gauge a x b / diameter | - / 1.4 mm |
| Stripping length | 8 mm |
Material data - contact
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
|---|---|
| Contact material | Cu alloy |
| Surface characteristics | hot-dip tin-plated |
Material data - housing
| Insulating material | PA |
|---|---|
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
Material data – actuating element
| Insulating material | POM |
|---|---|
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | HB |
Dimensions for the product
| Dimensional drawing | |
|---|---|
| Caption | Schematic representation – for additional information, see product range drawing in the Download Center |
| Length [ l ] | 19.05 mm |
| Height [ h ] | 11.75 mm |
| Pitch | 2.5 mm |
| Height (without solder pin) | 11.75 mm |
| Dimension a | 15 mm |
Packaging information
| Type of packaging | packed in cardboard |
|---|---|
| Pieces per package | 50 |
| Denomination packing units | Pcs. |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C |
Termination and connection method
| Conductor connection test | The stripped-off ends of the largest conductor can be completely inserted in the opening of the terminal point without using excessive force. |
|---|---|
| Test result | Test passed |
| Test – repeated connection and release | Test passed |
| Test for conductor damage and slackening | IEC 60999-1:1999-11 |
| Test passed |
Pull-out test
| Pull-out test | Test passed IEC 60999-1:1999-11 |
|---|---|
| IEC 60999-1:1999-11 | |
| Test passed | |
| Conductor cross section / conductor type / tensile force | 0.2 mm² solid > 10 N |
| 0.2 mm² stranded > 10 N | |
| 0.5 mm² solid > 20 N | |
| 0.5 mm² stranded > 20 N |
Mechanical tests according to standard
| Test specification | IEC 61984 |
|---|---|
| Visual test | Test passed IEC 60512-1-1:2002-02 |
| Dimensional test | Test passed IEC 60512-1-2:2002-02 |
| Resistance of marking | Test passed IEC 60068-2-70:1995-12 |
| Result | Test passed |
| Specification | IEC 60512-13-2:2006-02 |
| No. of cycles | 25 |
| Insertion strength per pos. approx. | 8 N |
| Withdraw strength per pos. approx. | 6 N |
| Polarization and coding | Test passed IEC 60512-13-5:2006-02 20 N |
| Test force | 20 N |
| Result | Test passed |
| Specification | IEC 60512-15-1:2008-05 |
| Test force per pos. | 24 N |
Air clearances and creepage distances
| Specification | IEC 60664-1:1992-10 + A1:2000-02 + A2:2002-05 |
|---|---|
| Insulating material group | I |
| Comparative tracking index (IEC 60112:2003-01) | CTI 600 |
| Voltage | 100 V |
| Rated insulation voltage (III/3) | 100 V |
| Rated insulation voltage (III/2) | 160 V |
| Rated insulation voltage (II/2) | 320 V |
| Rated surge voltage (III/3) | 1.5 kV |
| Rated surge voltage (III/2) | 2.5 kV |
| Rated surge voltage (II/2) | 2.5 kV |
| Minimum clearance - inhomogeneous field (III/3) | 0.8 mm |
| Minimum clearance - inhomogeneous field (III/2) | 1.5 mm |
| Minimum clearance - inhomogeneous field (II/2) | 1.5 mm |
| Minimum creepage distance value (III/3) | 1.8 mm |
| Minimum creepage distance value (III/2) | 0.8 mm |
| Minimum creepage distance value (II/2) | 1.6 mm |
Mechanical tests (A)
| Test specification | IEC 61984 |
|---|---|
| Insertion strength per pos. approx. | 8 N |
| Withdraw strength per pos. approx. | 6 N |
| Polarization when inserted requirement >20 N | Test passed |
| Contact holder in insert requirements >20 N | Test passed |
Durability tests (B)
| Specification | IEC 60512-9-1:2010-03 |
|---|---|
| Contact resistance R1 | 2 mΩ |
| Insertion/withdrawal cycles | 25 |
| Contact resistance R2 | 2.2 mΩ |
| Impulse withstand voltage at sea level | 2.95 kV |
| Power-frequency withstand voltage | 1.39 kV |
| Insulation resistance, neighboring positions | 80 GΩ |
Thermal tests (C)
| Specification | IEC 60512-5-1:2002-02 |
|---|---|
| Number of positions | 12 |
| Conductor cross section | 0.5 mm² |
| Test current | 4 A DC |
| Upper limiting temperature requirements <100 °C | Test passed |
Climatic tests (D)
| Specification | ISO 6988:1985-02 |
|---|---|
| Cold stress | -40 °C/2 h |
| Thermal stress | 100 °C/168 h |
| Corrosive stress | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Impulse withstand voltage at sea level | 2.95 kV |
| Power-frequency withstand voltage | 1.39 kV |
Environmental and durability tests (E)
| Specification | IEC 61984:2008-10 |
|---|---|
| Result, degree of protection, IP code | Finger safety with IP20 test finger |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
eCl@ss
| eCl@ss 4.0 | 272607xx |
|---|---|
| eCl@ss 4.1 | 27260701 |
| eCl@ss 5.0 | 27260701 |
| eCl@ss 5.1 | 27260701 |
| eCl@ss 6.0 | 27260704 |
| eCl@ss 7.0 | 27440402 |
| eCl@ss 8.0 | 27440309 |
| eCl@ss 9.0 | 27440309 |
UNSPSC
| UNSPSC 6.01 | 30211810 |
|---|---|
| UNSPSC 7.0901 | 39121409 |
| UNSPSC 11 | 39121409 |
| UNSPSC 12.01 | 39121409 |