PHOENIX CONTACT FTP-2/3 SERVICE FTP-2/3 SERVICE 3069465 PHOENIX CONTACT Test plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FTP-2/3 SERVICE 3069465 PHOENIX CONTACT Test plug

FTP-2/3 SERVICE

3069465

PHOENIX CONTACT

1 Pcs.

Test plug Test connector, nominal voltage: 400 V, nominal current: 24 A, Dimensioning cross-section: 2.5 mm², colour: red Test plug, nom. voltage: 400 V, nominal current: 24 A, Rated cross section: 2.5 mm2, color: red

Automation > Test plug for terminal blocks
Enclosures connectivity

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Configured as an FTP-2/3 SERVICE 3069465 PHOENIX CONTACT Test plug, this component facilitates temporary connections between testing devices and complex wiring systems during maintenance or troubleshooting procedures. Test plug terminal blocks are widely integrated into electrical distribution panels to streamline metering tasks and enhance technician safety during diagnostic work. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Test plug terminal block
  • Number of positions: 3
  • Pitch: 8.2 mm
  • Number of connections: 6
  • Number of rows: 1
  • Potentials: 3
  • Data management status Article revision: 02
  • Insulation characteristics Overvoltage category: III
  • Rated surge voltage: 4 kV
  • Maximum power dissipation for nominal condition: 1.31 W
  • Test surge voltage: 5 kV
  • Nominal cross section: 6 mm²
  • Test socket torque: 0.5
  • Note: The conductor cross section depends on the cable lug used
  • Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
  • Conductor cross section, flexible [AWG]: 20 ... 14 (converted acc. to IEC)

More info

▲
Technical data

Product properties
Product typeTest plug terminal block
Number of positions3
Pitch8.2 mm
Number of connections6
Number of rows1
Potentials3
Data management status
Article revision02
Insulation characteristics
Overvoltage categoryIII

Electrical properties
Rated surge voltage4 kV
Maximum power dissipation for nominal condition1.31 W
Test surge voltage5 kV

Connection data
Nominal cross section6 mm²
Test socket torque0.5
NoteThe conductor cross section depends on the cable lug used
Conductor cross section flexible0.5 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]20 ... 14 (converted acc. to IEC)
Nominal current24 A
Maximum load current24 A
Nominal voltage400 V AC/DC
Nominal cross section2.5 mm²

Dimensions
Width27.7 mm
Height86 mm
Pitch8.2 mm

Material specifications
Colorred (RAL 3001)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

Mounting
Mounting typeInsertion in base strip

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.