FTP-2/3 SERVICE 3069465 PHOENIX CONTACT Test plug
FTP-2/3 SERVICE
3069465
PHOENIX CONTACT
1 Pcs.
Automation > Test plug for terminal blocks
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configured as an FTP-2/3 SERVICE 3069465 PHOENIX CONTACT Test plug, this component facilitates temporary connections between testing devices and complex wiring systems during maintenance or troubleshooting procedures. Test plug terminal blocks are widely integrated into electrical distribution panels to streamline metering tasks and enhance technician safety during diagnostic work. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Test plug terminal block
- Number of positions: 3
- Pitch: 8.2 mm
- Number of connections: 6
- Number of rows: 1
- Potentials: 3
- Data management status Article revision: 02
- Insulation characteristics Overvoltage category: III
- Rated surge voltage: 4 kV
- Maximum power dissipation for nominal condition: 1.31 W
- Test surge voltage: 5 kV
- Nominal cross section: 6 mm²
- Test socket torque: 0.5
- Note: The conductor cross section depends on the cable lug used
- Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
- Conductor cross section, flexible [AWG]: 20 ... 14 (converted acc. to IEC)
More info
▲| Product type | Test plug terminal block |
| Number of positions | 3 |
| Pitch | 8.2 mm |
| Number of connections | 6 |
| Number of rows | 1 |
| Potentials | 3 |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Overvoltage category | III |
| Rated surge voltage | 4 kV |
| Maximum power dissipation for nominal condition | 1.31 W |
| Test surge voltage | 5 kV |
| Nominal cross section | 6 mm² |
| Test socket torque | 0.5 |
| Note | The conductor cross section depends on the cable lug used |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 20 ... 14 (converted acc. to IEC) |
| Nominal current | 24 A |
| Maximum load current | 24 A |
| Nominal voltage | 400 V AC/DC |
| Nominal cross section | 2.5 mm² |
| Width | 27.7 mm |
| Height | 86 mm |
| Pitch | 8.2 mm |
| Color | red (RAL 3001) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | Insertion in base strip |