View larger
EMD-FL-C-10 2866022 PHOENIX CONTACT Monitoring relay
EMD-FL-C-10
2866022
PHOENIX CONTACT
1 Pcs.
Automation > Current monitoring relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact EMD-FL-C-10 is a specialized current monitoring relay engineered to track electrical loads and protect automated processes against abnormal current fluctuations. Such monitoring units are widely deployed in industrial switchgear to ensure continuous operational safety and prevent equipment wear.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
- Product type: Current monitoring relay
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Article revision: 03
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 2
- Service life electrical: 2x 10 5 cycles at ohmic load, 1000 VA
- Maximum power dissipation for nominal condition: 1 W
- Mains type: 1-phase
- Rated insulation voltage: 300 V
- Rated surge voltage: 4 kV
- Supply Supply voltage range: 24 V AC ... 240 V AC -15 % ... +10 %
- Nominal power consumption: 4.5 VA (1.5 W)
- Input name: Measuring input
More info
▲| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Current monitoring relay |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
| Service life electrical | 2x 105cycles at ohmic load, 1000 VA |
| Maximum power dissipation for nominal condition | 1 W |
| Mains type | 1-phase |
| Rated insulation voltage | 300 V |
| Rated surge voltage | 4 kV |
| Supply | |
| Supply voltage range | 24 V AC ... 240 V AC -15 % ... +10 % |
| 24 V DC ... 240 V DC -20 % ... +25 % | |
| Nominal power consumption | 4.5 VA (1.5 W) |
| Input name | Measuring input |
| Measured value | DC, AC sine |
| Input current range | 0 mA ... 100 mA (Connection terminals: I1 and GND) |
| 0 A ... 1 A (Connection terminals: I2 and GND) | |
| 0 A ... 10 A (Connection terminals: I3 and GND) | |
| Overload capacity | 800 mA (at IN= 100 mA) |
| 3 A (at IN= 1 A) | |
| 12 A (at IN= 10 A) | |
| Input resistance current input | 470 mΩ (at IN= 100 mA) |
| 47 mΩ (at IN= 1 A) | |
| 5 mΩ (at IN= 10 A) | |
| Frequency range | 48 Hz ... 400 Hz |
| Maximum temperature coefficient | < 0.1 %/K |
| Setting range for response delay | 0.1 s ... 10 s |
| Setting range for starting delay | 0 s ... 10 s |
| Min. setting range | 5 % ... 95 % (from IN) |
| Max. setting range | 10 % ... 100 % (from IN) |
| Function | Overcurrent |
| Undercurrent | |
| Window | |
| Error memory | |
| Basic accuracy | ± 5 % (of scale end value) |
| Setting accuracy | ≤ 5 % (of scale end value) |
| Repeat accuracy | ≤ 2 % |
| Recovery time | 500 ms |
| Switching | |
| Contact switching type | 2 floating changeover contacts |
| Maximum switching voltage | 250 V AC (in acc. with IEC 60664-1) |
| Interrupting rating (ohmic load) max. | 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing) |
| 1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing) | |
| Output fuse | 5 A (fast-blow) |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.25 mm² ... 2.5 mm² |
| Conductor cross section AWG | 20 ... 14 |
| Width | 22.5 mm |
| Height | 90 mm |
| Depth | 113 mm |
| Color | green (RAL 6021) |
| Housing insulation material | Polyamide PA, self-extinguishing |
| Ambient conditions | |
| Degree of protection (Housing) | IP40 (Housing) |
| Degree of protection (Connection terminal blocks) | IP20 (Connection terminal blocks) |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| -25 °C ... 40 °C (corresponds to UL 508) | |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Permissible humidity (operation) | 15 % ... 85 % |
| CE | |
| Certificate | CE-compliant |
| UL, USA/Canada | |
| Identification | UL/C-UL Listed UL 508 |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Noise immunity | EN 61000-6-2 |
| Noise emission | EN 61000-6-4 |
| Standards/regulations | EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | on standard DIN rail NS 35 in accordance with EN 60715 |
| Mounting position | any |