PSI-REP-DNET CAN 2313423 PHOENIX CONTACT Repeater
PSI-REP-DNET CAN
2313423
PHOENIX CONTACT
1 Pcs.
Automation > PLC communication module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSI-REP-DNET CAN is a repeater utilized to regenerate and extend signal propagation across industrial network lines. Signal repeaters of this variety help maintain communication integrity over long cable runs by compensating for attenuation and electromagnetic interference in harsh plant environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Note on application Note on application: Only for industrial use
- Utilization restriction CCCex note: Use in potentially explosive areas is not permitted in China.
- Product type: Interface converter
- MTTF: 1091 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Data management status Article revision: 09
- Electrical isolation: VCC // TBUS // CAN A // CAN B
- Maximum power dissipation for nominal condition: 1.32 W
- Test voltage data interface/power supply: 1.5 kV rms (50 Hz, 1 min.)
- Rated insulation voltage: 85 V DC (In accordance with EN/IEC 60079-7, Annex H)
- Supply Supply voltage range: 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
- Nominal supply voltage: 24 V DC
- Typical current consumption: 55 mA (24 V DC)
- Max. current consumption: 80 mA
- Switching Output name: Relay output
- Number of outputs: 1
- Contact switching type: N/C contact
More info
▲| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Product type | Interface converter |
| MTTF | 1091 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| 514 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| 208 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | |
| MTBF | 823 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 170 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| Data management status | |
| Article revision | 09 |
| Electrical isolation | VCC // TBUS // CAN A // CAN B |
| Maximum power dissipation for nominal condition | 1.32 W |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Rated insulation voltage | 85 V DC (In accordance with EN/IEC 60079-7, Annex H) |
| Supply | |
| Supply voltage range | 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
| Nominal supply voltage | 24 V DC |
| Typical current consumption | 55 mA (24 V DC) |
| Max. current consumption | 80 mA |
| ≤ 2 A (For operation in a joining station, via the DIN rail connector) | |
| Function | |
| Status and diagnostic indicators | LEDs: VCC (supply voltage), NET A (Mod/Net status port A), NET B (Mod/Net status port B), ACT (activity/data traffic) |
| Switching | |
| Output name | Relay output |
| Number of outputs | 1 |
| Contact switching type | N/C contact |
| Minimum switching voltage | 10 V DC |
| Maximum switching voltage | 30 V DC |
| Limiting continuous current | 500 mA |
| Supply | |
| Stripping length | 7.00 mm |
| Tightening torque | 0.56 Nm ... 0.79 Nm |
| Bit distortion, input | ± 35 % |
| Bit distortion, output | < 6.25 % |
| Bit delay | One telegram length (EXTENDED) |
| Signal | CAN |
| CANopen® | |
| DeviceNet™ | |
| Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen® | |
| Transmission speed | ≤ 1 Mbps (Configurable via DIP switches) |
| Connection method | COMBICON plug-in screw terminal block |
| No. of channels | 2 (CAN_High / CAN_Low) |
| Transmission length | ≤ 5000 m (Dependent on the data rate and the protocol used) |
| Number of bus devices | ≤ 64 (per potential segment) |
| ≤ 63 (DeviceNet™, can be addressed logically) | |
| ≤ 128 (CANopen®, can be addressed logically) | |
| Termination resistor | 124 Ω (Integrated and ready to be switched) |
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Max. AWG conductor cross section, flexible | 14 |
| Min. AWG conductor cross section, flexible | 24 |
| Single-wire/terminal point, rigid AWG max. | 14 |
| Single-wire/terminal point, rigid AWG min. | 24 |
| Stripping length | 7 mm |
| Transmission medium | 2-wire twisted pair, shielded |
| Transmission method | CSMA/CA |
| File format/coding | Bit stuffing, NRZ |
| Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen® | |
| Transmission speed | ≤ 1 Mbps (Configurable via DIP switches) |
| Connection method | COMBICON plug-in screw terminal block |
| No. of channels | 2 (CAN_High / CAN_Low) |
| Transmission length | ≤ 5000 m (Dependent on the data rate and the protocol used) |
| Number of bus devices | ≤ 64 (per potential segment) |
| ≤ 63 (DeviceNet™, can be addressed logically) | |
| ≤ 128 (CANopen®, can be addressed logically) | |
| Termination resistor | 124 Ω (Integrated and ready to be switched) |
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Max. AWG conductor cross section, flexible | 14 |
| Min. AWG conductor cross section, flexible | 24 |
| Single-wire/terminal point, rigid AWG max. | 14 |
| Single-wire/terminal point, rigid AWG min. | 24 |
| Transmission medium | 2-wire twisted pair, shielded |
| Transmission method | CSMA/CA |
| File format/coding | Bit stuffing, NRZ |
| Dimensional drawing | |
| Width | 35 mm |
| Height | 111 mm |
| Depth | 121 mm |
| Color (Housing) | green (RAL 6021) |
| Material (Housing) | PA 6.6-FR |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF07ATEX2313533X |
| Note | Please follow the special installation instructions in the documentation! |
| UKEX | |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIMA22UKEX2313423X |
| UL, USA/Canada | |
| Identification | 508 Listed |
| Corrosive gas test | |
| Identification | ISA-S71.04-1985 G3 Harsh Group A |
| Shipbuilding | |
| Identification | DNV GL |
| DNV GL data | |
| Temperature | B |
| Humidity | A |
| Vibration | A |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Noise immunity | EN 61000-6-2 |
| Noise emission | EN 55011 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | ± 6 kV |
| Discharge in air | ± 8 kV |
| Comments | Criterion B |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 3 GHz |
| Field intensity | 10 V/m |
| Comments | Criterion A |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | ± 2 kV |
| Signal | ± 2 kV |
| Comments | Criterion B |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge current load (surge) | |
| Input | ± 0.5 kV |
| Signal | ± 1 kV |
| Comments | Criterion B |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| Comments | Criterion A |
| Voltage | 10 V |
| Emitted interference | |
| Standards/regulations | EN 55011 |
| Comments | Class A, industrial applications |
| Criteria | |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Free from substances that could impair the application of coating | VDMA 24364:2018-05 |
| Mounting type | DIN rail mounting |
| Assembly note | The product can be snapped onto all 35 mm DIN rails in accordance with EN 60715. |