View larger
MKDSP 25/ 3-15,00 GY BD:U-W 1712510 PHOENIX CONTACT Terminal for printed circuit board, rated voltage: 1000 ..
MKDSP 25/ 3-15,00 GY BD:U-W
1712510
PHOENIX CONTACT
25 Pcs.
Connectors > Printed circuit board terminal
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact MKDSP 25/ 3-15,00 GY BD:U-W is a heavy-duty terminal for printed circuit board applications requiring high current and voltage handling. These robust terminal blocks are commonly integrated into industrial power supplies, motor drives, and heavy electrical distribution hardware. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: PCB terminal block
- Product Family: MKDSP 25
- Product Line: COMBICON Terminals XL
- Number of poles: 3
- Step: 15 mm
- Number of connections: 3
- Number of rows: 1
- Number of potentials: 3
- Pin Layout: Linear Pinning
- Number of Welding Pins per Potential: 4
- Data maintenance status Article review: 02
- Rated Current I N: 125 A
- Rated voltage U N: 1000 V
- Sizing voltage (III/3): 1000 V
- Sizing impulse voltage (III/3): 8 kV
- Sizing voltage (III/2): 1000 V
More info
▲| Product Type | PCB terminal block |
| Product Family | MKDSP 25 |
| Product Line | COMBICON Terminals XL |
| Number of poles | 3 |
| Step | 15 mm |
| Number of connections | 3 |
| Number of rows | 1 |
| Number of potentials | 3 |
| Pin Layout | Linear Pinning |
| Number of Welding Pins per Potential | 4 |
| Data maintenance status | |
| Article review | 02 |
| Rated Current IN | 125 A |
| Rated voltage UN | 1000 V |
| Sizing voltage (III/3) | 1000 V |
| Sizing impulse voltage (III/3) | 8 kV |
| Sizing voltage (III/2) | 1000 V |
| Sizing Impulse Voltage (III/2) | 8 kV |
| Sizing voltage (II/2) | 1000 V |
| Sizing Impulse Voltage (II/2) | 8 kV |
| Connection technology | |
| type | Standard |
| Nominal cross-section | 35 mm² |
| Conductor connection | |
| Link | Screw connection with cage |
| Rigid conductor cross-section | 0.5 mm² ... 35 mm² |
| Flexible conductor cross-section | 0.5 mm² ... 35 mm² |
| Conductor cross-section AWG | 20 ... 2 |
| Flexible conductor cross-section with cable lug without plastic collar | 1 mm² ... 35 mm² |
| Flexible conductor cross-section with mounted lug and plastic collar | 1.5 mm² ... 35 mm² |
| 2 conductors of identical cross-section, rigid | 0.5 mm² ... 6 mm² |
| 2 conductors of identical flexible cross-section | 0.5 mm² ... 6 mm² |
| 2 conductors of the same flexible cross-section with ferrule without plastic collar | 0.5 mm² ... 4 mm² |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 0.5 mm² ... 16 mm² |
| Length of the section to be stripped | 18 mm |
| Appliance type screw head | Pozidriv with longitudinal slit (Z2L) |
| Tightening torque | 2.5 Nm ... 4.5 Nm ( |
| Indications for aluminium conductors | |
| Cross-section / tightening torque / cable shape | Line cross-section:35 mm²; Tightening torque:4.5 Nm; Cable Shape: Circular, Rigid, Class 1 (RE) |
| Test Specification | DIN VDE 0276-603 (VDE 0276-603):2010-03 |
| Note for conductor preparation | To ensure safe and long-lasting contact of the aluminium conductor, it is recommended to observe the following measures: remove the oxide layer on the end of the conductor with a blade and immediately immerse the end in petroleum jelly (neither acidic, nor alkaline, i.e. neutral). Repeat this procedure each time you connect again. |
| Mounting type | Wave Soldering |
| Pin Layout | Linear Pinning |
| Processing Instructions | |
| Process | Wave Soldering |
| Material information - contacts | |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact Material | Cu Alloy |
| Surface Finish | Galvanic tin plating |
| Metal Surface, Connection Point (Surface Layer) | Tin (5 - 7 μm Sn) |
| Metal Surface Welding Area (Surface Layer) | Tin (5 - 7 μm Sn) |
| Material information - case | |
| Color (Case) | Grey (7042) |
| Insulation material | PA |
| Insulation Material Group | The |
| CTI according to IEC 60112 | 600 |
| Combustibility class according to UL 94 | V0 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| Dimensioned Drawing | |
| Step | 15 mm |
| Width [w] | 45 mm |
| Height [h] | 43.5 mm |
| Length [l] | 31 mm |
| Installation Height | 39 mm |
| Weld Shank Length [P] | 4.5 mm |
| Shank sizes | 1.2 x 1.2 mm |
| Printed circuit board design | |
| Bore diameter | 1.6 mm |
| Conductor Integrity and Stability Test | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Test passed |
| Tensile test | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | 0.5 mm² / rigid / > 20 N |
| 0.5 mm² / flexible / > 20 N | |
| 35 mm² / semi-rigid / > 190 N | |
| 35 mm² / flexible / > 190 N | |
| Ambient Temperature Test | |
| Test Specification | DIN EN 60947-7-4 (VDE 0611-7-4):2014-08 |
| Heating verification requirement | The sum of the ambient temperature and the heating of the PCB terminal should not exceed the upper limit of the temperature. |
| Short-term current resistance | |
| Test Specification | DIN EN 60947-7-4 (VDE 0611-7-4):2014-08 |
| Insulation Resistance | |
| Test Specification | DIN EN 60512-3-1:2003-01 |
| Insulation Resistance Between Contiguous Poles | > 5 MΩ |
| Creepage and Creepage Distances | |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulation Material Group | The |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 1000 V |
| Rated impulse voltage (III/3) | 8 kV |
| Minimum clearance value - inhomogeneous range (III/3) | 8 mm |
| Minimum creepage value (III/3) | 12.5 mm |
| Rated Isolation Voltage (III/2) | 1000 V |
| Rated impulse voltage (III/2) | 8 kV |
| Minimum creepage value - inhomogeneous range (III/2) | 8 mm |
| Minimum creepage value (III/2) | 8 mm |
| Rated Isolation Voltage (II/2) | 1000 V |
| Rated Impulse Voltage (II/2) | 8 kV |
| Minimum creepage value - inhomogeneous range (II/2) | 8 mm |
| Minimum creepage value (II/2) | 8 mm |
| Vibration test | |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Test duration per axle | 2.5 h |
| Test Directions | X, Y, and Z axis |
| Glow Wire Test | |
| Test Specification | DIN EN 60695-2-10 (VDE 0471-2-10):2001-11 |
| Temperature | 850 °C |
| Duration of application | 5 s |
| Aging | |
| Test Specification | DIN EN 60947-7-4 (VDE 0611-7-4):2014-08 |
| Environmental conditions | |
| Ambient temperature (operating) | -40 °C ... 100 °C (Depending on current flow curve/derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Packaging | Packed in carton |