View larger
MKDS 3/ 8-5,08 GY 1128164 PHOENIX CONTACT Terminal for printed circuit board, pitch: 5,08 mm, number of pole..
MKDS 3/ 8-5,08 GY
1128164
PHOENIX CONTACT
50 Pcs.
Connectors > Printed circuit board terminal
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact part number MKDS 3/ 8-5,08 GY is a terminal for printed circuit boards engineered to provide secure and enduring connections for industrial control systems. These terminal blocks bridge field wiring with internal circuitry, ensuring reliable performance across power distribution and signal routing applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: PCB terminal block
- Product Family: MKDS 3
- Product Line: COMBICON Terminals M
- Number of poles: 8
- Step: 5.08 mm
- Number of rows: 1
- Pin Layout: Linear Pinning
- Number of Welding Pins per Potential: 1
- Data maintenance status Article review: 00
- Rated Current I N: 24 A
- Rated voltage U N: 400 V
- Sizing voltage (III/3): 250 V
- Sizing impulse voltage (III/3): 4 kV
- Sizing voltage (III/2): 400 V
- Sizing Impulse Voltage (III/2): 4 kV
- Sizing voltage (II/2): 630 V
More info
▲| Product Type | PCB terminal block |
| Product Family | MKDS 3 |
| Product Line | COMBICON Terminals M |
| Number of poles | 8 |
| Step | 5.08 mm |
| Number of rows | 1 |
| Pin Layout | Linear Pinning |
| Number of Welding Pins per Potential | 1 |
| Data maintenance status | |
| Article review | 00 |
| Rated Current IN | 24 A |
| Rated voltage UN | 400 V |
| Sizing voltage (III/3) | 250 V |
| Sizing impulse voltage (III/3) | 4 kV |
| Sizing voltage (III/2) | 400 V |
| Sizing Impulse Voltage (III/2) | 4 kV |
| Sizing voltage (II/2) | 630 V |
| Sizing Impulse Voltage (II/2) | 4 kV |
| Connection technology | |
| type | Modular PCB terminal block |
| Nominal cross-section | 2.5 mm² |
| Conductor connection | |
| Link | Screw connection with cage |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 2.5 mm² |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 2.5 mm² |
| 2 conductors of identical cross-section, rigid | 0.2 mm² ... 1.5 mm² |
| 2 conductors of identical flexible cross-section | 0.2 mm² ... 1.5 mm² |
| 2 conductors of the same flexible cross-section with ferrule without plastic collar | 0.25 mm² ... 0.75 mm² |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 0.5 mm² ... 1.5 mm² |
| Length of the section to be stripped | 8 mm |
| Appliance type screw head | Longitudinal slit (L) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Mounting type | Wave Soldering |
| Pin Layout | Linear Pinning |
| Material information - contacts | |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact Material | Cu Alloy |
| Surface Finish | Galvanic tin plating |
| Metal Surface, Connection Point (Surface Layer) | Tin (4 - 8 μm Sn) |
| Metal Surface Welding Area (Surface Layer) | Tin (4 - 8 μm Sn) |
| Material information - case | |
| Color (Case) | Grey (7042) |
| Insulation material | PA |
| Insulation Material Group | The |
| CTI according to IEC 60112 | 600 |
| Combustibility class according to UL 94 | V0 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| Note for use | A predefined tightening torque must always be observed for secure connection. Especially in the case of two- and three-pole PCB terminals, the single contact soldering tip may not block them. For this reason, the terminals must be reinforced when connecting (fixed by hand, reinforcement on the housing). |
| Dimensioned Drawing | |
| Step | 5.08 mm |
| Width [w] | 40.64 mm |
| Height [h] | 23 mm |
| Length [l] | 11.2 mm |
| Installation Height | 18 mm |
| Weld Shank Length [P] | 5 mm |
| Shank sizes | 0.9 x 0.9 mm |
| Printed circuit board design | |
| Shank Distance | 15.24 mm |
| Bore diameter | 1.3 mm |
| Conductor Integrity and Stability Test | |
| Test Specification | DIN EN 60998-2-1 (VDE 0613-2-1):2005-03 |
| Result | Test passed |
| Tensile test | |
| Test Specification | DIN EN 60998-2-1 (VDE 0613-2-1):2005-03 |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | 0.2 mm² / rigid / > 10 N |
| 0.2 mm² / flexible / > 10 N | |
| 4 mm² / rigid / > 60 N | |
| 2.5 mm² / flexible / > 50 N | |
| Torque test | |
| Test Specification | DIN EN 60998-2-1 (VDE 0613-2-1):2005-03 |
| Ambient Temperature Test | |
| Test Specification | DIN EN 60998-1 (VDE 0613-1):2005-03 |
| Heating verification requirement | Temperature rise ≤ 45 K |
| Insulation Resistance | |
| Test Specification | DIN EN 60998-1 (VDE 0613-1):2005-03 |
| Insulation Resistance Between Contiguous Poles | 109Ω |
| Creepage and Creepage Distances | |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulation Material Group | The |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 250 V |
| Rated impulse voltage (III/3) | 4 kV |
| Minimum clearance value - inhomogeneous range (III/3) | 3 mm |
| Minimum creepage value (III/3) | 3.2 mm |
| Note on the Connection Section | In case of conductor connected by 4 mm² (rigid). |
| Rated Isolation Voltage (III/2) | 400 V |
| Rated impulse voltage (III/2) | 4 kV |
| Minimum creepage value - inhomogeneous range (III/2) | 3 mm |
| Minimum creepage value (III/2) | 3 mm |
| Rated Isolation Voltage (II/2) | 630 V |
| Rated Impulse Voltage (II/2) | 4 kV |
| Minimum creepage value - inhomogeneous range (II/2) | 3 mm |
| Minimum creepage value (II/2) | 3.2 mm |
| Vibration test | |
| Test Specification | DIN EN 60068-2-6:1996-05 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Test duration per axle | 2.5 h |
| Test Directions | X, Y, and Z axis |
| Glow Wire Test | |
| Test Specification | DIN EN 60998-1 (VDE 0613-1):2005-03 |
| Temperature | 850 °C |
| Duration of application | 5 s |
| Environmental conditions | |
| Ambient temperature (operating) | -40 °C ... 100 °C (Depending on current flow curve/derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Packaging | Packed in carton |