View larger
REL-MR- 24AC/21-21AU 2961464 PHOENIX CONTACT Single relay
REL-MR-24AC/21-21AU
2961464
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This single relay unit, designated as the REL-MR- 24AC/21-21AU 2961464 PHOENIX CONTACT Single relay, functions as a core switching component within industrial control assemblies, providing electrical isolation and precise command execution.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Complete with socket (EF003359): No
- With detachable clamps (EF003340): No
- With LED indication (EF005950): No
- Rated control supply voltage AC 50 Hz (EF003978): 18.7 V
- Rated control supply voltage AC 60 Hz (EF003979): 18.7 V
- Voltage type for actuating (EF008242): AC
- Drive, polarization (EF003355): Polarity free
- Drive, switching attitude (EF003356): Mono stable
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 2
- Type of switch contact (EF003358): Single contact
- With forced-guided contacts (EF003357): No
- Material of contact surface (EF004020): Gold
- Nominal current (EF000001): 0.032 A
- Width (EF000008): 12.7 mm
More info
▲Key Commercial Data
| Orderkey | 2961464 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 304 (C-5-2017) |
| GTIN | 4017918937874 |
| Weight per Piece (excluding packing) | 16.110 g |
| Custom tariff number | 85364190 |
| Country of origin | AT (Austria) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Coil side
| Nominal input voltage UN | 24 V AC |
|---|---|
| Mains frequency | 50/60 Hz |
| Typical input current at UN | 32 mA (at 50 Hz) |
| 24 mA (At 60 Hz) | |
| Typical response time | 3 ms ... 12 ms (depending on phase relation) |
| Typical release time range | 2 ms ... 9 ms (depending on phase relation) |
| Coil resistance | 350 Ω ±10 % (at 20 °C) |
| Power dissipation for nominal condition | 0.77 W |
Contact side
| Contact type | 2 PDT |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| Minimum switching voltage | 100 mV (at 10 mA) |
| Min. switching current | 1 mA (at 24 V) |
| Maximum inrush current | 50 mA |
| Limiting continuous current | 50 mA |
| Interrupting rating (ohmic load) max. | 1.2 W (at 24 V DC) |
Contact side (with destroyed gold layer)
| Contact material | AgNi |
|---|---|
| Note | the following values are applicable if a gold layer is destroyed |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (at 10 mA) |
| Limiting continuous current | 8 A |
| Maximum inrush current | 50 A (20 ms) |
| Min. switching current | 10 mA (At 5 V) |
| Interrupting rating (ohmic load) max. | 190 W (at 24 V DC) |
| 85 W (at 48 V DC) | |
| 60 W (at 60 V DC) | |
| 44 W (at 110 V DC) | |
| 60 W (at 220 V DC) | |
| 2000 VA (for 250 V AC) | |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.2 A (at 110 V, DC13) | |
| 0.2 A (at 250 V, DC13) | |
| 2 A (at 24 V, AC15) | |
| 2 A (at 120 V, AC15) | |
| 2 A (at 250 V, AC15) |
General
| Test voltage relay winding/relay contact | 5 kV AC (50 Hz, 1 min.) |
|---|---|
| Test voltage relay contact/relay contact | 2.5 kV AC (50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Degree of protection | RT III (wash-proof) |
| Mechanical service life | 1x 107cycles |
| Service life, electrical | see diagram |
| Mounting position | any |
| Assembly instructions | Can be aligned without spacing (> 70 °C ≥ 2.5 mm) |
| Net weight (SAP) | 16.11 g |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| EN 61810-1 | |
| Insulation | Basic insulation |
| Degree of pollution | 3 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |