View larger
MINI MCR-EX-SD-16-50-LP 1157869 PHOENIX CONTACT Ex i-Valve control block to activate solenoid valves with in..
MINI MCR-EX-SD-16-50-LP
1157869
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Deployed in explosion-protected automation circuits, the MINI MCR-EX-SD-16-50-LP 1157869 PHOENIX CONTACT Ex i-Valve control block to activate solenoid valves with in.. acts as a specialized valve control module. These modules manage power delivery to field instrumentation located in hazardous locations while maintaining rigorous galvanic isolation standards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Valve control module
- Product Family: MINI Analog Pro
- Galvanic isolation Overvoltage Category: II (≤ 5000 m)
- Degree of pollution: 2 (≤ 5000 m)
- Rated insulation voltage: 300 V Eff
- Test voltage: 2.5 kV AC (50 Hz, 60 s)
- isolation: Dual/reinforced insulation
- Rated insulation voltage: 265 V Eff
- Rated insulation voltage: 251 V Eff
- Feeding Supply voltage range: Self-powered in a loop, no external power supply required
- Input: < 1.4 W
- Signal: Voltage Number of inputs: 1
- Input signal, voltage: 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
- Signal: Voltage Number of outputs: 1
- Output voltage: ≥ 10.7 V DC (50 mA)
- Output Resistor: ≥ 103 Ω (internal resistance R the )
More info
▲| Product Type | Valve control module |
| Product Family | MINI Analog Pro |
| Galvanic isolation | |
| Overvoltage Category | II (≤ 5000 m) |
| Degree of pollution | 2 (≤ 5000 m) |
| Galvanic Isolation Input/Output IEC/EN 61010-1 | |
| Standards/Provisions | IEC/EN 61010-1 |
| Rated insulation voltage | 300 VEff |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| isolation | Dual/reinforced insulation |
| Galvanic Isolation Input/Output IEC/EN 60079-11 | |
| Standards/Provisions | IEC/EN 60079-11 |
| Rated insulation voltage | 265 VEff |
| Galvanic Isolation Input/Output IEC/EN 60079-7 | |
| Standards/Provisions | IEC/EN 60079-7 |
| Rated insulation voltage | 251 VEff |
| Feeding | |
| Supply voltage range | Self-powered in a loop, no external power supply required |
| Input | < 1.4 W |
| Signal: Voltage | |
| Number of inputs | 1 |
| Input signal, voltage | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
| Signal: Voltage | |
| Number of outputs | 1 |
| Output voltage | ≥ 10.7 V DC (50 mA) |
| Output Resistor | ≥ 103 Ω (internal resistance Rthe) |
| Current limiting | > 50 mA |
| Response time | < 50 ms |
| No-load voltage | > 16 V DC |
| Resistant to short circuits | Yes |
| Conductor cross-section AWG | (converted according to IEC) |
| Link | Screw connection |
| Stripping length | 10 mm |
| Thread | M3 |
| Rigid conductor cross-section | 0.2 mm² ... 1.5 mm² (with lug) |
| 0.14 mm² ... 2.5 mm² (without lug) | |
| Flexible conductor cross-section | 0.14 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 (flexible) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Ex Installation (EPL) | Gc |
| Div. 2 | |
| Ex i Circuits (EPL) | Ga |
| From | |
| But | |
| Div. 1 | |
| Technical safety data | |
| Max. internal choke Lthe | negligible |
| Max. C internal capacitythe | 11 nF |
| Max. output voltage Uor | 19.2 V |
| Max. output current Ior | 185 mA |
| Max. output power Por | 888 mW |
| Maximum safety voltage Um | 253 V AC |
| 125 V DC | |
| IIA (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor | 7 mH / 6.1 μF |
| IIB/IIIC (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 4 mH / 1.53 μF |
| IIC (Simple Current Circuit): Max. External Inductivity Lor/ Max. external capacity Cor | 0.8 mH / 240 nF |
| I (simple current circuit): Max. external inductivity Lor/ Max. external capacity Cor | 10 mH / 8.7 μF |
| width | 6.2 mm |
| height | 109.81 mm |
| Depth | 119.2 mm |
| Environmental conditions | |
| Degree of protection | Ip20 |
| Ambient temperature (operating) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Area of use at high altitudes (IEC/EN 61010-1) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operating) | -40 °C ... 63 °C |
| Rated insulation voltage | 300 VEff(Input/Output) |
| isolation | Dual/reinforced insulation |
| Area of use at high altitudes (IEC/EN 61010-1) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operating) | -40 °C ... 56 °C |
| Rated insulation voltage | 300 VEff(Input/Output) |
| isolation | Dual/reinforced insulation |
| Area of use at high altitudes (IEC/EN 61010-1) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operating) | -40 °C ... 49 °C |
| Rated insulation voltage | 150 VEff(Input/Output) |
| isolation | Dual/reinforced insulation |
| Area of use at high altitudes (IEC/EN 60079-11) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operating) | -40 °C ... 63 °C |
| Maximum safety voltage Um | 121 V AC |
| 110 V DC | |
| Rated insulation voltage | 150 VEff(Input/Output) |
| Area of use at high altitudes (IEC/EN 60079-11) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operating) | -40 °C ... 56 °C |
| Maximum safety voltage Um | 33 V AC/DC |
| Rated insulation voltage | 60 VEff(Input/Output) |
| Area of use at high altitudes (IEC/EN 60079-11) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operating) | -40 °C ... 49 °C |
| Maximum safety voltage Um | 33 V AC/DC |
| Rated insulation voltage | 60 VEff(Input/Output) |
| High-altitude range of applications (IEC/EN 60079-7) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operating) | -40 °C ... 63 °C |
| Rated insulation voltage | 162 VEff(Input/Output) |
| High-altitude range of applications (IEC/EN 60079-7) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operating) | -40 °C ... 56 °C |
| Rated insulation voltage | 60 VEff(Input/Output) |
| High-altitude range of applications (IEC/EN 60079-7) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operating) | -40 °C ... 49 °C |
| Rated insulation voltage | 60 VEff(Input/Output) |
| Ec | |
| Certificate | CE Compliance |
| ATEX | |
| Marking | II (1) G [Ex ia Ga] IIC |
| II (1) D [Ex ia Da] IIIC | |
| II 3 (1) G Ex ec [ia Ga] IIC T4 Gc | |
| I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 21 ATEX 8651 X |
| IECEx | |
| Marking | [Ex ia Ga] IIC |
| [Ex ia Da] IIIC | |
| Ex ec [ia Ga] IIC T4 Gc | |
| [Ex ia Ma] The | |
| Certificate | IECEx TUR 21.0043 X |
| UKCA Ex (UKEX) | |
| Marking | II (1) G [Ex ia Ga] IIC |
| II (1) D [Ex ia Da] IIIC | |
| II 3 (1) G Ex ec [ia Ga] IIC T4 Gc | |
| I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 21 UKEX 7021 X |
| CCC / China-Ex | |
| Marking | [Ex ia Ga] IIC |
| [Ex ia Da] IIIC | |
| Ex ec [ia Ga] IIC T4 Gc | |
| Certificate | 2023122310116238 |
| UL, USA / Canada | |
| Marking | UL 61010-2-201 |
| Safety Integrity Level (SIL, IEC 61508) | |
| Marking | 3 |
| Immunity to disturbances | IEC/EN 61000-6-2 |
| IEC/EN 61326-3-2 | |
| Electromagnetic Compatibility | Tested according to the following standards and requirements: EN 61326-1 Use in an industrial environment, NAMUR NE 21 |
| Noise emission | IEC/EN 61000-6-4 |
| GB Standard | |
| Standards/Provisions | GB/T 3836.1 |
| GB/T 3836.3 | |
| GB/T 3836.4 | |