Limit value switches Universal setting temperature limit value switch with shut-off relay output for connection of 2, 3 and 4 conductor heat resistances and thermocouples. Configurable via DIP switches or software. Push-in connection technology

Automation > Isolation amplifier
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Limit value switches such as the Phoenix Contact MINI MCR-2-T-REL-PT monitor industrial sensor thresholds and trigger switching contacts when critical parameters are exceeded. These modules protect machinery by delivering dependable relay-based alarms or interlock signals directly to safety or control equipment.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated supply voltage DC (EF007078): 9.6 V
  • Number of input ranges -60 mV ... +60 mV (EF006927): 0
  • Number of input ranges -100 mV ... +100 mV (EF006912): 0
  • Number of input ranges -300 mV ... +300 mV (EF006920): 0
  • Number of input ranges -500 mV ... +500 mV (EF006926): 0
  • Number of input ranges -1 V ... +1 V (EF006906): 0
  • Number of input ranges -2 V ... +2 V (EF006913): 0
  • Number of input ranges -2.5 V ... +2.5 V (EF006915): 0
  • Number of input ranges -5 V ... +5 V (EF006923): 0
  • Number of input ranges -10 V ... +10 V (EF006909): 0
  • Number of input ranges -20 V ... +20 V (EF006917): 0
  • Number of input ranges 0 mV ... 60 mV (EF006905): 0
  • Number of input ranges 0 mV ... 100 mV (EF006893): 0
  • Number of input ranges 0 mV ... 200 mV (EF006898): 0
  • Number of input ranges 0 mV ... 300 mV (EF006901): 0
  • Number of input ranges 0 mV ... 500 mV (EF006904): 0

More info

Key Commercial Data

Orderkey2905633
Packing unit1 pc
Catalog pagePage 92 (C-5-2017)
GTIN4046356999847
Weight per Piece (excluding packing)99.990 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height110.5 mm
Depth120.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Input data

Available input sourcesResistance thermometers
Sensor types (RTD) that can be usedPt, Ni, Cu sensors
Connection technology2, 3, 4-wire
Sensor input currentapprox. 200 µA
Max. permissible overall conductor resistance≤ 25 Ω (Per line, RTD in 3- or 4-wire technology)
≤ 50 Ω (Per line, RTD in 2-wire technology)
Linear resistance measuring range0 Ω ... 4000 Ω
Linear mV signal range-500 mV ... 500 mV
Available input sourcesThermocouples
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L

Switching output

Output nameRelay output
Contact type1 N/O contact
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC
240 V AC (UL)
Limiting continuous current6 A
Min. switching current100 mA (12 V DC)
Mechanical service life2x 107cycles
Setting range of the response delay0 s ... 10 s (can be set freely via software)
Internal hysteresiscan be set freely via software
Max. switching current6 A (for 250 V AC)

Power supply

Nominal supply voltage24 V DC
Supply voltage range9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption44 mA (12 V DC)
22 mA (24 V DC)
Power consumption570 mW

Connection data

Connection methodPush-in connection
Single conductor/terminal point, solid, with ferrule, min.0.14 mm²
Single conductor/terminal point, solid, with ferrule, max.2.5 mm²
Single conductor/terminal point, solid, without ferrule, min.0.14 mm²
Single conductor/terminal point, solid, without ferrule, max.2.5 mm²
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.2.5 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible12
Stripping length10 mm

General

No. of channels1
Maximum temperature coefficient0.01 %/K
Switching point accuracy< 0.1 %
Status displayYellow LED (switching output)
Electrical isolationReinforced insulation in accordance with IEC 61010-1
Overvoltage categoryII
Degree of pollution2
Rated insulation voltage300 V
Test voltage, input/output/supply3 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgray
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, Group IIC T4A
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Electrical isolationReinforced insulation in accordance with IEC 61010-1
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, Group IIC T4A
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.