View larger
MINI MCR-2-RPSS-I-2I 2905628 PHOENIX CONTACT Repeater power supply
MINI MCR-2-RPSS-I-2I
2905628
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The MINI MCR-2-RPSS-I-2I is a Phoenix Contact repeater power supply designed to power 2-wire transmitters and transparently transmit analog 4-20 mA current signals. Such units are commonly installed in process automation networks to provide reliable galvanic isolation and eliminate common-mode interference in multi-channel measurement loops.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
- Product type: Repeater power supply
- Product family: MINI Analog Pro
- No. of channels: 2
- Type: Signal conditioner
- Configuration: DIP switches
- Data management status Article revision: 02
- Insulation characteristics: GB Standard Overvoltage category: II
- Pollution degree: 2
- Electrical isolation: 4-way isolation
- Limit frequency (3 dB): > 1 kHz
- Signal transmission behavior: In = Out
- Step response (10-90%): < 400 µs
- Maximum temperature coefficient: 0.0075 %/K
- Maximum transmission error: 0.05 % (of final value)
- Test voltage: 3 kV AC (50 Hz, 60 s)
More info
▲| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Repeater power supply |
| Product family | MINI Analog Pro |
| No. of channels | 2 |
| Type | Signal conditioner |
| Configuration | DIP switches |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics: GB Standard | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Electrical isolation | 4-way isolation |
| Limit frequency (3 dB) | > 1 kHz |
| Signal transmission behavior | In = Out |
| Step response (10-90%) | < 400 µs |
| Maximum temperature coefficient | 0.0075 %/K |
| Maximum transmission error | 0.05 % (of final value) |
| Electrical isolation Input/output/power supply | |
| Rated insulation voltage | 300 Vrms |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
| Supply | |
| Nominal supply voltage | 24 V DC |
| Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Typical current consumption | 40 mA (For 24 V DC and in signal duplicator mode) |
| 65 mA (For 24 V DC and in power supply duplicator mode) | |
| 75 mA (For 12 V DC and in signal duplicator mode) | |
| 130 mA (For 12 V DC and in power supply duplicator mode) | |
| Power consumption | 1.6 W (at IOUT= 20 mA, 500 Ω load) |
| Signal: Current | |
| Description of the input | Sensor circuit |
| Number of inputs | 1 |
| Current input signal | 0 mA ... 20 mA (Signal duplicator mode) |
| 4 mA ... 20 mA (Power supply and signal duplicator mode) | |
| Input resistance current input | 90 Ω (+1.6 V) |
| Transmitter supply voltage | > 19.5 V |
| Signal: Current | |
| Number of outputs | 2 |
| Non-load voltage | < 20 V |
| Current output signal | 0 mA ... 20 mA (Signal duplicator mode) |
| 4 mA ... 20 mA (Power supply and signal duplicator mode) | |
| Max. current output signal | 25 mA |
| Load/output load current output | ≤ 500 Ω (per channel) |
| Ripple | < 20 mVPP(500 Ω) |
| Connection method | Screw connection |
| Stripping length | 10 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² (with ferrule) |
| 0.14 mm² ... 2.5 mm² (without ferrule) | |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Ex installation (EPL) | Gc |
| Div. 2 |
| Data communication (bypass) | |
| HART function | Yes |
| Limit frequency (3 dB) | 1 kHz |
| Status display | Green LED (supply voltage) |
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
| Color | gray (RAL 7042) |
| Housing material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Ambient conditions | |
| Degree of protection | IP20 (not assessed by UL) |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 3 G Ex ec ic IIC T4 Gc |
| Certificate | BVS 19 ATEX E 047 X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex ec ic IIC T4 Gc |
| Certificate | PxCIF21UKEX2902000X |
| IECEx | |
| Identification | Ex ec ic IIC T4 Gc |
| Certificate | IECEx BVS 19.0041X |
| CCC / China-Ex | |
| Identification | Ex nA ic IIC T4 Gc |
| UL, USA/Canada | |
| Identification | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T5 | |
| Class I, Zone 2, Group IIC T5 | |
| Shipbuilding approval | |
| Certificate | DNV GL TAA000021E Rev. 1 |
| EAC Ex | |
| Identification | 2Ex ec ic IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00081 |
| DNV GL data | |
| Temperature | B |
| Humidity | B |
| Vibration | A |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
| Electromagnetic HF field | |
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| Fast transients (burst) | |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Conducted interference | |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Electrical isolation | 4-way isolation |
| GB Standard | |
| Standards/regulations | GB 3836.1 |
| GB 3836.4 | |
| GB 3836.8 | |
| Mounting type | DIN rail mounting |
| Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting position | any |