The Phoenix Contact MACX MCR-SL-CAC-5-I-UP 2810625 current transducers deliver galvanic isolation and precise signal conversion for demanding industrial electrical measurement loops. These units protect automation hardware from voltage surges while providing reliable feedback across automation networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
- Product type: Current transducer
- Data management status Article revision: 14
- Insulation characteristics Overvoltage category: III
- Pollution degree: 2
- Maximum power dissipation for nominal condition: < 0.9 W (24 V DC)
- Protective circuit: Surge protection; 35 V suppressor diode
- Step response (10-90%): ≤ 300 ms
- Maximum temperature coefficient: < 0.02 %/K
- Temperature coefficient, typical: < 0.015 %/K
- Maximum transmission error: ≤ 0.5 % (of nominal range value under nominal conditions)
- Reverse polarity protection: yes
- Rated insulation voltage: 300 V AC (to earth)
- Electrical isolation Input/output Test voltage: 4 kV AC (50 Hz, 60 s)
- Electrical isolation Output/supply Test voltage: 2 kV AC (50 Hz, 60 s)
- Supply Supply voltage range: 19.2 V AC/DC ... 253 V AC/DC
More info
▲| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Current transducer |
| Data management status | |
| Article revision | 14 |
| Insulation characteristics | |
| Overvoltage category | III |
| Pollution degree | 2 |
| Maximum power dissipation for nominal condition | < 0.9 W (24 V DC) |
| < 3.4 W (230 V AC) | |
| Protective circuit | Surge protection; 35 V suppressor diode |
| Step response (10-90%) | ≤ 300 ms |
| 200 ms | |
| Maximum temperature coefficient | < 0.02 %/K |
| Temperature coefficient, typical | < 0.015 %/K |
| Maximum transmission error | ≤ 0.5 % (of nominal range value under nominal conditions) |
| Reverse polarity protection | yes |
| Rated insulation voltage | 300 V AC (to earth) |
| Electrical isolation Input/output | |
| Test voltage | 4 kV AC (50 Hz, 60 s) |
| Electrical isolation Output/supply | |
| Test voltage | 2 kV AC (50 Hz, 60 s) |
| Supply | |
| Supply voltage range | 19.2 V AC/DC ... 253 V AC/DC |
| Max. current consumption | < 33 mA (24 V DC) |
| Power consumption | < 0.8 W (24 V DC) |
| Measurement | |
| Configurable/programmable | Via DIP switches |
| Input current range | 0 A AC ... 1 A AC (configurable) |
| 0 A AC ... 5 A AC (configurable) | |
| Voltage input signal | ≤ 300 V AC |
| Input impedance | < 50 mΩ |
| Overload capacity | 2 x IN (continuous) |
| Surge strength | 20 x IN(1 s) |
| Nominal frequency fN | 50 Hz |
| Frequency measuring range | 45 Hz ... 65 Hz |
| Curve type | Sine |
| Signal: Current | |
| Configurable/programmable | Via DIP switches |
| Non-load voltage | 15 V |
| Current output signal | 0 mA ... 20 mA (configurable) |
| 4 mA ... 20 mA (configurable) | |
| Max. current output signal | 25 mA |
| Load/output load current output | < 500 Ω (20 mA) |
| Ripple | < 10 mVPP(500 Ω / 20 mA) |
| Status display | LED red (error), LED green (ready) |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Data communication (bypass) | |
| Limit frequency (3 dB) | approx. 3 Hz |
| Item dimensions | |
| Width | 22.5 mm |
| Height | 104 mm |
| Depth | 114.5 mm |
| Color | gray (RAL 7042) |
| Housing material | Polyamide PA non-reinforced |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 65 °C |
| -4 °F ... 149 °F | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C (-40 °F ... 185 °F) |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 3 G Ex nA IIC T4 Gc X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex nA IIC T4 Gc |
| Certificate | PxCIF21UKEX2810638X |
| UL, USA/Canada | |
| Identification | UL 508 Recognized |
| EAC Ex | |
| Identification | 2Ex nA IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00078 |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Comments | Criterion A |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Comments | Criterion B |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge current load (surge) | |
| Comments | Criterion B |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Mounting type | DIN rail mounting |
| Mounting position | any |