The Phoenix Contact ME-IO 18,8 EB/FE 10U TBUS 7035 acts as a lower part of the housing, providing the structural base and integrated bus connector interface for modular DIN rail devices. Base elements like this securely anchor electronics while enabling internal power and data distribution across adjacent modules. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- General: Refer to the data sheet for the range in the download area.
- General: Material of contact pads for bus connector, galvanic gold (hard gold)
- Product type: Enclosure bottom part
- Max. number of positions: 48 (pitch: 3.45 mm)
- Type: Lower housing part with metal foot catch
- Housing type: DIN rail housing
- Ventilation openings present: yes
- Housing series: ME-IO
- Cross section AWG: (converted acc. to IEC)
- Width: 18.9 mm
- Height: 120.6 mm
- Depth: 82.85 mm
- Depth from top edge of DIN rail: 76.25 mm
- PCB design PCB thickness: 1.4 mm ... 1.8 mm
- Color: light grey (7035)
- Flammability rating according to UL 94: V0
More info
▲| General | Refer to the data sheet for the range in the download area. |
| General | Material of contact pads for bus connector, galvanic gold (hard gold) |
| Product type | Enclosure bottom part |
| Max. number of positions | 48 (pitch: 3.45 mm) |
| 32 (pitch: 5 mm) | |
| Type | Lower housing part with metal foot catch |
| Housing type | DIN rail housing |
| Ventilation openings present | yes |
| Housing series | ME-IO |
| Cross section AWG | (converted acc. to IEC) |
| Dimensional drawing | |
| Width | 18.9 mm |
| Height | 120.6 mm |
| Depth | 82.85 mm |
| Depth from top edge of DIN rail | 76.25 mm |
| PCB design | |
| PCB thickness | 1.4 mm ... 1.8 mm |
| Color | light grey (7035) |
| Flammability rating according to UL 94 | V0 |
| Surface characteristics | untreated |
| Housing material | Polyamide |
| Power dissipation single housing for 20 °C | |
| Ambient temperature | 20 °C |
| Reduction factor | 1 |
| Mounting position | vertical |
| Power dissipation | 11.8 W |
| Power dissipation single housing for 30 °C | |
| Ambient temperature | 30 °C |
| Reduction factor | 0.81 |
| Mounting position | vertical |
| Power dissipation | 9.6 W |
| Power dissipation single housing for 40 °C | |
| Ambient temperature | 40 °C |
| Reduction factor | 0.63 |
| Mounting position | vertical |
| Power dissipation | 7.5 W |
| Power dissipation single housing for 50 °C | |
| Ambient temperature | 50 °C |
| Reduction factor | 0.46 |
| Mounting position | vertical |
| Power dissipation | 5.5 W |
| Power dissipation single housing for 60 °C | |
| Ambient temperature | 60 °C |
| Reduction factor | 0.31 |
| Mounting position | vertical |
| Power dissipation | 3.7 W |
| Vibration test | |
| Specification | IEC 60068-2-6:2007-12 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.15 mm (10 Hz ... 58.1 Hz) |
| Acceleration | 2g (58.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
| Test directions | X-, Y- and Z-axis |
| Glow-wire test | |
| Specification | IEC 60695-2-11:2014-02 |
| Temperature | 850 °C |
| Time of exposure | 30 s |
| Thermal stability / ball thrust test | |
| Specification | IEC 60695-10-2:2014-02 |
| Temperature | 125 °C |
| Test duration | 1 h |
| Force | 20 N |
| Mechanical strength / tumbling barrel | |
| Specification | IEC 60068-2-31:2008-05 |
| Height of fall | 50 cm |
| Frequency | 50 |
| Shocks | |
| Specification | IEC 60068-2-27:2008-02 |
| Pulse shape | Semi-sinusoidal |
| Acceleration | 15g |
| Shock duration | 11 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Test for substances that would hinder coating with paint or varnish | |
| Specification | VDMA 24364:2018-05 |
| Degree of protection (IP code) | |
| Specification | IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08 |
| Ambient conditions | |
| Max. IP code to attain | IP20 |
| Ambient temperature (operation) | -40 °C ... 105 °C (depending on power dissipation) |
| Ambient temperature (storage/transport) | -40 °C ... 55 °C |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Relative humidity (storage/transport) | 80 % |
| Number of PCB holders | 1 |
| Type of PCB mount | Latching |
| Total PCB surface | 8500 mm² |
| Thickness of the PCB | 1.4 mm ... 1.8 mm |
| Mounting type | DIN rail mounting |
| Mounting position | Vertical (horizontal DIN rail) |
| Type of packaging | packed in cardboard |