View larger
ME 22,5 UT/FE GY 1109642 PHOENIX CONTACT DIN rail housing, Lower housing part with metal foot catch, tall de..
ME 22,5 UT/FE GY
1109642
PHOENIX CONTACT
10 Pcs.
Automation > Extruded profile modular housing
Housing (HS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact DIN rail housing, lower housing part with metal foot catch, tall de, identified by part number ME 22,5 UT/FE GY, offers a sturdy foundation for mounting electronic components within industrial control cabinets. This category of enclosure securely houses internal circuitry and facilitates orderly organization across standard DIN rail configurations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of enclosure (EF003086): Closed
- Housing connectable (EF003088): No
- Colour (EF000007): Grey
- RAL-number (EF000116): 7042
- Width (EF000008): 22.6 mm
- Height (EF000040): 99 mm
- Depth (EF000049): 107.3 mm
More info
▲Item properties
| Brief article description | Mounting base housing |
|---|---|
| Type | ME 22,5 UT/FE GY |
| Order No. | 1109642 |
| Housing type | DIN rail housing |
| Type | Lower housing part with metal foot catch, tall design |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 55 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 105 °C (depending on power dissipation) |
| Relative humidity (storage/transport) | 80 % |
Power dissipation, single housing at 20 °C
| Ambient temperature | 20 °C |
|---|---|
| Reduction factor | 1 |
| Mounting position | vertical |
| Power dissipation | 6.1 W |
Power dissipation, single housing at 30 °C
| Ambient temperature | 30 °C |
|---|---|
| Reduction factor | 0.91 |
| Mounting position | vertical |
| Power dissipation | 5.5 W |
Power dissipation, single housing at 40 °C
| Ambient temperature | 40 °C |
|---|---|
| Reduction factor | 0.81 |
| Mounting position | vertical |
| Power dissipation | 4.9 W |
Power dissipation, single housing at 50 °C
| Ambient temperature | 50 °C |
|---|---|
| Reduction factor | 0.7 |
| Mounting position | vertical |
| Power dissipation | 4.3 W |
Power dissipation, single housing at 60 °C
| Ambient temperature | 60 °C |
|---|---|
| Reduction factor | 0.57 |
| Mounting position | vertical |
| Power dissipation | 3.5 W |
Mechanical strength/tumbling barrel
| Specification | IEC 60998-1:2002-12 |
|---|---|
| Height of fall | 50 cm |
| Number of drop cycles | 10 |
Vibration test
| Specification | IEC 60068-2-6:2007-12 |
|---|---|
| Frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.15 mm (10 - 58.1 Hz) |
| Acceleration | 2g (58.1 - 150 Hz) |
| Test duration per axis | 2.5 h |
| Test directions | X-, Y- and Z-axis |
Shock
| Specification | IEC 60068-2-27:2008-02 |
|---|---|
| Pulse shape | Half-sine |
| Acceleration | 15g |
| Shock duration | 11 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
Thermostability (Ball Thrust Test)
| Specification | IEC 60695-10-2:2014-02 |
|---|---|
| Temperature | 125 °C |
| Test duration | 1 h |
| Force | 20 N |
Test for assessing the risk of fire (glow wire)
| Specification | DIN EN 60695-2-11 (VDE 0471-2-11):2014-11 |
|---|---|
| Temperature | 850 °C |
| Time of exposure | 30 s |
Degrees of protection provided by housings (IP code)
| Specification | IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08 |
|---|---|
| Result, degree of protection, IP code | IP20 |