View larger
PSR-MC37-3NO-1NC-24DC-SC 2702411 PHOENIX CONTACT Safety relays
PSR-MC37-3NO-1NC-24DC-SC
2702411
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Safety relays monitor safety circuits and protective equipment, interrupting electrical energy when a hazard is detected to protect operators and machinery. The Phoenix Contact PSR-MC37-3NO-1NC-24DC-SC module offers robust screw terminal connections for reliable integration into industrial control panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.1 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
More info
▲Key Commercial Data
| Orderkey | 2702411 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 254 (C-6-2017) |
| GTIN | 4055626276960 |
| Weight per Piece (excluding packing) | 183.880 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 60 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
|---|---|
| 19.2 V DC ... 30 V DC | |
| Rated control supply current IS | typ. 70 mA |
| Power consumption at US | typ. 1.68 W |
| Inrush current | 2 A (Δt = 300 µs at Us) |
| Protective circuit | Surge protection Suppressor diode |
| Protection against polarity reversal for rated control circuit supply voltage |
Digital inputs
| Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off; at S12 and S22) |
|---|---|
| Input current range "0" signal | 0 mA ... 2 mA (for safe Off; at S12 and S22) |
| Inrush current | < 5 mA (Δt = 500 µs, for Us/Ix at S12) |
| > -5 mA (Δt = 500 µs, for Us/Ix at S22) | |
| < 10 mA (Δt = 500 µs, for Us/Ix at S35) | |
| Current consumption | < 4 mA (with Us/Ixto S12/S22) |
| < 0.5 mA (with Us/Ixto S35) | |
| Filter time | max. 3 ms (at S12, S22; test pulse width; blanking pulses/dark test) |
| 1 s (at S12, S22; test pulse rate; blanking pulses/dark test) | |
| Where test pulse width ≤ 1 ms: test pulse rate = 5 x test pulse width | |
| max. 1 ms (at S12, S22; test pulse width; switch-on pulses/light test) | |
| 100 ms (at S12, S22; test pulse rate; switch-on pulses/light test) | |
| Unless switch-on pulses/light tests are safety-related, they should be disabled. | |
| Voltage at input/start and feedback circuit | 24 V DC -20 % / +25 % |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | safety-related N/O contacts |
| Number of outputs | 3 (undelayed) |
| Contact type | 3 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A (observe derating) |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Sq. Total current | 72 A2(observe derating) |
| Switching capacity | min. 50 mW |
| Switching frequency | 0.5 Hz |
| Interrupting rating (ohmic load) max. | 1500 VA (250 V AC, τ = 0 ms) |
| For additional values, see load curve | |
| Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
| 40 W (48 V DC, τ = 40 ms) | |
| 36 W (60 V DC, τ = 40 ms) | |
| 35 W (110 V DC, τ = 40 ms) | |
| 33 W (220 V DC, τ = 40 ms) | |
| 1500 VA (250 V AC, τ = 40 ms) | |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 5 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG (N/O contact) |
Relay outputs: return current/signaling current path
| Output name | Signaling current path |
|---|---|
| Output description | non-safety-related N/C contact |
| Number of outputs | 1 (undelayed) |
| Contact type | 1 signaling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC | |
| Limiting continuous current | 1 A |
| Inrush current | min. 10 mA |
| max. 6 A (Δt = 100 ms) | |
| Sq. Total current | 1 A2 |
| Switching capacity | min. 50 mW |
| Switching frequency | 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 1 A gL/gG |
Alarm outputs
| Output description | non-safety-related |
|---|---|
| Number of outputs | 1 (digital) |
| Voltage | 23 V DC (Us- 1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 1 A (Δt = 5 ms at Us) |
| Short-circuit protection | Yes |
Times
| Typical pickup time at US | < 100 ms (when controlled via A1) |
|---|---|
| Typical response time at US | < 100 ms (automatic start) |
| Typical release time at US | < 20 ms (when controlled via A1 or S12) |
| Restart time | < 1 s (Boot time) |
| Recovery time | < 500 ms |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 183.88 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing color | yellow |
| Operating voltage display | 1 x green LED |
| Status display | 3 x green LED |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 60664-1:2008 |
| Rated insulation voltage | 250 V AC |
| 250 V AC | |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths |
| Basic insulation 4 kV between all current paths and housing | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Shock | 15g for Δt = 11 ms (continuous shock: 10g for Δt = 16 ms) |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |