View larger
MINI MCR-SL-UI-REL 2864480 PHOENIX CONTACT Limit value switches
MINI MCR-SL-UI-REL
2864480
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact model MINI MCR-SL-UI-REL is a limit value switch designed for monitoring analog process signals and triggering protective switching actions in electrical installations.
Limit switches are commonly integrated into control cabinets to compare incoming sensor values against preset thresholds, protecting machinery by activating alarms or safety relays when limits are exceeded. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area
- Product type: Limit value switch
- Product family: MINI Analog
- No. of channels: 1
- Configuration: DIP switches
- Data management status Article revision: 12
- Insulation characteristics Overvoltage category: II
- Pollution degree: 2
- Functionality Configuration: DIP switches
- Electrical isolation: 3-way isolation
- Electrical isolation between input and output: yes
- Maximum power dissipation for nominal condition: < 405 mW
- Switching point accuracy: < 0.05 %
- Step response (0–99%): < 35 ms
- Maximum temperature coefficient: < 0.02 %/K
- Test voltage: 1.5 kV AC (50 Hz, 60 s)
More info
▲| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Limit value switch |
| Product family | MINI Analog |
| No. of channels | 1 |
| Configuration | DIP switches |
| Data management status | |
| Article revision | 12 |
| Insulation characteristics | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Functionality | |
| Configuration | DIP switches |
| Electrical isolation | 3-way isolation |
| Electrical isolation between input and output | yes |
| Maximum power dissipation for nominal condition | < 405 mW |
| Switching point accuracy | < 0.05 % |
| Step response (0–99%) | < 35 ms |
| Maximum temperature coefficient | < 0.02 %/K |
| Electrical isolation Input/power supply | |
| Rated insulation voltage | 50 V AC/DC |
| Test voltage | 1.5 kV AC (50 Hz, 60 s) |
| Insulation | Basic insulation in accordance with IEC/EN 61010 |
| Supply | |
| Nominal supply voltage | 24 V DC ±15 % |
| Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Max. current consumption | < 14 mA (at 24 V DC) |
| Power consumption | < 330 mW (at 24 V DC) |
| Signal: Voltage/current | |
| Number of inputs | 1 |
| Voltage input signal | 0 V ... 10 V |
| Max. voltage input signal | 30 V |
| Current input signal | 0 mA ... 20 mA |
| Max. current input signal | 100 mA |
| Input resistance of voltage input | > 100 kΩ |
| Input resistance current input | 50 Ω |
| Specification of the switching point | With 25-speed potentiometer |
| Switching: Relay | |
| Contact switching type | 1 changeover contact |
| Contact material | AgSnO2, hard gold-plated |
| Maximum switching voltage | 250 V AC |
| 240 V AC (UL) | |
| Limiting continuous current | 2 A |
| Setting range of the response delay | 0 s ... 10 s (0 s, 1 s, 2 s, 3 s, 4 s, 6 s 8 s, 10 s) |
| Internal hysteresis | 0.1 %, 1 %, 2.5 %, 5 % |
| Signal | |
| Number of outputs | 1 |
| Connection method | Screw connection |
| Stripping length | 12 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 12 |
| Dimensional drawing | |
| Width | 6.2 mm |
| Height | 93.1 mm |
| Depth | 101.2 mm |
| Color | green (RAL 6021) |
| Housing material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 65 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| UKCA | |
| Certificate | UKCA-compliant |
| UL, USA | |
| Identification | Class I, Zone 2, AEx nA nC IIC T5 |
| UL, USA/Canada | |
| Identification | UL 508 Recognized |
| UL, Canada | |
| Identification | Class I, Zone 2, Ex nA nC IIC T5 Gc |
| Shipbuilding approval | |
| Certificate | DNV GL TAA00002R0 |
| DNV GL data | |
| Temperature | B |
| Humidity | B |
| Vibration | B |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
| Electromagnetic HF field | |
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 5 % |
| Fast transients (burst) | |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 5 % |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge current load (surge) | |
| Comments | Criterion B |
| Conducted interference | |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 5 % |
| Electrical isolation | 3-way isolation |
| Mounting type | DIN rail mounting |
| Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting position | any |